#HDMI 3(C/S : E8 C0)
EDID Block 0, Bytes
0 | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A | B | C | D | E | F |
00 | 00 | FF | FF | FF | FF | FF | FF | 00 | 1E | 6D | 01 | 00 | 01 | 01 | 01 | 01 |
10 | 01 | 17 | 01 | 03 | 80 | A0 | 5A | 78 | 0A | EE | 91 | A3 | 54 | 4C | 99 | 26 |
20 | 0F | 50 | 54 | A1 | 08 | 00 | 31 | 40 | 45 | 40 | 61 | 40 | 71 | 40 | 81 | 80 |
30 | 01 | 01 | 01 | 01 | 01 | 01 | 02 | 3A | 80 | 18 | 71 | 38 | 2D | 40 | 58 | 2C |
40 | 45 | 00 | 40 | 84 | 63 | 00 | 00 | 1E | 66 | 21 | 50 | B0 | 51 | 00 | 1B | 30 |
50 | 40 | 70 | 36 | 00 | 40 | 84 | 63 | 00 | 00 | 1E | 00 | 00 | 00 | FD | 00 | 3A |
60 | 3E | 1E | 53 | 10 | 00 | 0A | 20 | 20 | 20 | 20 | 20 | 20 | 00 | 00 | 00 | FC |
70 | 00 | 4C | 47 | 20 | 54 | 56 | 0A | 20 | 20 | 20 | 20 | 20 | 20 | 20 | 01 | E8 |
EDID Block 1, Bytes
0 | 0 | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | A | B | C | D | E | F |
80 | 02 | 03 | 3E | F1 | 4E | 10 | 9F | 04 | 13 | 05 | 14 | 03 | 02 | 12 | 20 | 21 |
90 | 22 | 15 | 01 | 29 | 3D | 06 | C0 | 15 | 07 | 50 | 09 | 57 | 07 | 7C | 03 | 0C |
A0 | 00 | 10 | 00 | B8 | 3C | 20 | C0 | 8E | 01 | 02 | 03 | 04 | 01 | 4F | 3F | FC |
B0 | 08 | 10 | 18 | 10 | 06 | 10 | 16 | 10 | 28 | 10 | E3 | 05 | 03 | 01 | 02 | 3A |
C0 | 80 | 18 | 71 | 38 | 2D | 40 | 58 | 2C | 45 | 00 | 40 | 84 | 63 | 00 | 00 | 1E |
D0 | 01 | 1D | 80 | 18 | 71 | 1C | 16 | 20 | 58 | 2C | 25 | 00 | 40 | 84 | 63 | 00 |
E0 | 00 | 9E | 01 | 1D | 00 | 72 | 51 | D0 | 1E | 20 | 6E | 28 | 55 | 00 | 40 | 84 |
F0 | 63 | 00 | 00 | 1E | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | 00 | C0 |
4.2. White Balance Adjustment
4.2.1. Overview
▪W/B adj. Objective &
(1)Objective: To reduce each Panel's W/B deviation
(2)
(3)Adjustment condition : normal temperature
1)Surrounding Temperature : 25 °C ± 5 °C
2)
3)Surrounding Humidity : 20 % ~ 80 %
4)Before White balance adjustment, Keep power on status, don’t power off
4.2.2. Adj. condition and cautionary items
(1)Lighting condition in surrounding area surrounding lighting should be lower 10 lux. Try to isolate adj. area into dark surrounding.
(2)Probe location: Color Analyzer
(3)Aging time
1)After Aging Start, Keep the Power ON status during 5 Minutes.
2)In case of LCD,
4.2.3. Equipment
(1)Color Analyzer:
(2)Adjustment Computer(During auto adj.,
(3)Adjustment Remote control
(4)Video Signal Generator
(Model: 217, Pattern: 49)
→Only when internal pattern is not available
▪Color Analyzer Matrix should be calibrated using
4.2.4. Equipment connection MAP
|
| Color Analyzer |
Probe |
| RS |
|
| Computer |
| RS | RS |
|
| |
|
| Pattern Generator |
| Signal Source |
|
| * If TV internal pattern is used, not needed |
4.2.5. Adj. Command (Protocol)
<Command Format>
START 6E A 50 A LEN A 03 A CMD A 00 A VAL A CS STOP
-LEN: Number of Data Byte to be sent
-CMD: Command
-VAL: FOS Data value
-CS: Checksum of sent data
-A: Acknowledge
Ex) [Send: JA_00_DD] / [Ack: A_00_okDDX]
▪
Explantion | ||||
[CMD | ID | DATA] | ||
| ||||
wb | 00 | 00 | Begin White Balance adjustment | |
wb | 00 | 10 | Gain adjustment(internal white pattern) | |
wb | 00 | 1f | Gain adjustment completed | |
wb | 00 | 20 | Offset adjustment(internal white pattern) | |
wb | 00 | 2f | Offset adjustment completed | |
wb | 00 | ff | End White Balance adjustment | |
(internal pattern disappears ) | ||||
|
|
|
Ex) wb 00 00
ja 00 ff
...
...
wb 00 1f → Gain adj. completed
*(wb 00 20(Start), wb 00 2f(end)) →
▪ Adj. Map
| Adj. item | Command | Data Range | Default | ||
| (lower caseASCII) | (Hex.) | (Decimal) | |||
|
| |||||
|
| CMD1 | CMD2 | MIN | MAX |
|
| R Gain | j | g | 00 | C0 |
|
| G Gain | j | h | 00 | C0 |
|
Cool | B Gain | j | i | 00 | C0 |
|
R Cut |
|
|
|
|
| |
|
|
|
|
|
| |
| G Cut |
|
|
|
|
|
| B Cut |
|
|
|
|
|
| R Gain | j | a | 00 | C0 |
|
| G Gain | j | b | 00 | C0 |
|
Medium | B Gain | j | c | 00 | C0 |
|
R Cut |
|
|
|
|
| |
|
|
|
|
|
| |
| G Cut |
|
|
|
|
|
| B Cut |
|
|
|
|
|
| R Gain | j | d | 00 | C0 |
|
| G Gain | j | e | 00 | C0 |
|
Warm | B Gain | j | f | 00 | C0 |
|
| R Cut |
|
|
|
|
|
| G Cut |
|
|
|
|
|
Copyright © | LG Electronics. Inc. All rights reserved. | - 17 - | LGE Internal Use Only |
Only for training and service purposes |
|
|