The accompanying diagram (Picture 7-2), along with your alarm’s manual should be consulted to ensure proper connection.

Normal open or Normal close type

Parallel connect COM end and GND end of the alarm detector (Provide external power to the alarm detector).

Parallel connect the Ground of the combo DVR and the ground of the alarm detector.

Connect the NC port of the alarm sensor to the combo DVR alarm input(ALARM)

Use the same ground with that of combo DVR if you use external power to the alarm device.

Alarm input public end should jump out with device power end. Alarm Device Connection Terminal

+12V GND COM PC

Alarm Device

Connection Terminal

ALARM

GND

+12V GND

PICTURE 7-2

7.2 ALARM OUTPUT

7.3 ALARM SETUP AND ACTIVATION

Once external alarms are properly connected, you can configure the DVR to activate them.

The Alarm interface can be selected from the

Setting menu.

PICTURE 7-2

The upper portion of this window is used to choose an alarm, its configuration and its type.

Alarm In – Select the alarm channel you are configuring.

Event Type – Choose between Local Input and Network Input

Enable – When this is selected the alarm response(s) in the bottom portion of this window are enabled.

Type – Alarms are either Normally Open (NO) or Normally Closed (NC)

PICTURE 7-3

The bottom portion of the window allows you to choose what actions the DVR will initiate when an alarm is activated along with scheduling when the alarms are active.

CHAPTER 7 ALARMS

The alarm output port should not be directly connected to a higher power load (greater than 1A) to avoid high current which may damage the relay. Use the co-contactor to establish the connection between the alarm output port and the load.

2 way relay alarm output (NO contact). Provides external power to external alarm device.

To avoid overloading, please read the following relay parameters sheet carefully.

RS485 A/B cable is for the A/B cable of the PTZ camera.

Period – This is for setting the schedule for when alarms are active. Clicking the Set button opens up a new window. Its operation is exactly like the setting window used to schedule motion detection and covered in Section 4.7.

You can set the schedule in up to six blocks of time for specific days of the week or by weekday and weekend.

Clicking the Set button next to the day drop down allows you to specify which days are work days and which are not.

PICTURE 7-4

PICTURE 7-5

56

57

Image 29
Contents Model QC40108 About this Manual Table of Contents Questions or Comments? Contact Us Troubleshooting Minimum Computer ConfigurationIntroduction Features and Specifications DVR Installation InstallationConnection ConnectionsVideo Output CamerasAudio Input and Output Virtual Keyboard ControlsMouse Control Num Name Function Remote ControlFront and Side Panels Basic OperationOperation Live ViewLogin LOGIN, Logout and Main MenuMain Menu Shortcut MenuRecording Search and PlaybackLogout Auto ResumeStart, Stop and Play SearchPlayback Video Clip ZoomBack-up Schedule Basic OperationMOTION, Video Loss and Camera Masking Detection Motion DetectionEvent Response Video LossCamera Masking Backup Menus MenusMain Menu Info MenuLOG BPSVersion Online UsersGeneral Setting MenuEncode Schedule Network AlarmDetect PAN/TILT/ZOOMDisplay DefaultAdvanced Alarm OutputHDD Manage AbnormalityShutdown TV AdjustRecord AccountPTZ Control and Setup Connecting a PTZ CameraSetup PAN/TILT/ZOOM CamerasPreset Setting PRESET/PATROL/PATTERN/SCANControl PatrolAlarm AlarmsAlarm Input Running PTZ FunctionsAlarms Alarm Output Alarm Setup and ActivationIs covered in .2 Ptzpicture 7-5Control and Setup INSTALLATION/REMOVALHard Disk Drive Hard Disk DriveCalculating the Recording Capacity of a Hard Disk Drive Video Resolution Frame BIT Space Format Rate Quality UsedAppendix TroubleshootingAppendix Minimum required configuration of a PC for remote connection Minimum Computer ConfigurationSee Products See Product WarrantyLiability Exclusions