Premier Mounts LPFM1532 installation instructions Wood Stud Installation

Page 4

LPFM1532

Wood Stud Installation

Prior to installation, the two (2) M6 x 75mm Phillips head locking screws must be removed. These two screws are located on the bottom of the LPFM1532.

Visual Centering Diamond - The visual centering diamond will allow you to determine the center of the wood stud. It will also allow you to determine the exact center for the flat panel placement on the wall. The visual centering diamond will work in conjunction with the visual stud guide.

Visual Stud Guide - The visual stud guide will allow you to determine exactly where both edges of the wood stud is within the wall. Once both edges of the wood stud have been located, the visual centering diamond will be directly over the exact center of the wood stud. Once the plate is in this position, the two mounting holes may be marked.

Directional Arrow

Visual Centering Diamond

Visual Stud Guide

Step 1. Place the wall plate against the wall with the directional arrow pointing up.

Step 2. Use a pencil to make a mark in the center of the visual centering diamond. This will be the center position of the flat panel.

Mark

Stud

Electronic

Studfinder

Center Line

Step 3. Use an electronic studfinder to locate the stud.

Step 4. Align the plate to the stud and visually verify the flat panel placement now that the stud has been located.

Step 5. Once the center of the stud has been located, mark the wall at the two (2) screw hole locations.

Step 6. Use a 1/8” bit and create pilot holes where the 2 markings were made.

 

Visual Stud Guide

1/8” Bit

#10 x 2” Screws

 

Pilot Hole

 

 

Drill

Step 7. Insert two (2) #10 X 2” screws into the pre-drllied pilot holes.

Step 8. Tighten the wall plate screws at this time.

Page 4

Installation Instructions

Image 4
Contents Installation Instructions Installation Instructions Parts List Installation Tools not suppliedWood Stud Installation Concrete Surface Installation Universal Spacers Installation Determining the Mounting HardwareAdapter Plate Installation Optional Cover Plate InstallationRecessed Vesa 75mm/100mm Pattern 200 x 200 Installation Flat Panel Installation Technical Specifications Warranty What is Not Covered LimitationsWhat Customers Must Do for Limited Warranty Service What Premier Mounts Will Do