3M 2220M manual Quick Start, ➊ ➋ ➌ ➍, Transmitter Battery Installation Transmitter Overview

Page 5

Quick Start

Transmitter Battery Installation

Transmitter Overview

Induction Direction

Dynatel220M Frequency

ƒHz

Off

On

Output Level

➊ ➋ ➌ ➍

1.Power OFF / Battery Level Indicator – Press and hold.. Display reads:.

“OK” with solid tone = good. “LO” with pulsing tone = low. “- -” with no tone = replace

2.Power ON / Frequency Select – Powers on the unit. When pressed repeatedly, it will cycle through the available frequency modes:.

a.Single audio frequency - 8 kHz.

b.Single radio frequency - 82 kHz.

c.Dual frequency – Both 8 kHz and 82 kHz are transmitted simultaneously.

3.Output Level – Toggles the output power level between Normal output and High output. Flag will flash over output icon on display when in High output mode.

4.Output Jack – Direct Connect and 3MDynatelDyna-Coupler Clamp port.

5.Induction Direction Arrows – Indicates orientation of transmitter in relationship to target path.

Image 5
Contents Operator Manual 3M DynatelContents Introduction Model Number Included in Equipment Package Optional 3M Dynatel AccessoriesStandard 3M Dynatel 2220M Locator Equipment Packages ➊ ➋ ➌ ➍ Transmitter Battery Installation Transmitter OverviewQuick Start  Warning Receiver Battery InstallationReceiver Overview ➍ ➎ ➌ ➏ ➐3M Dynatel Dyna-Coupler Clamp Transmitter OperationsDirect Connection Induction Method Receiver Setup Initial SettingsLine Locate Frequencies Selection Default Receiver OperationsPage 50 Hz / 60 Hz Line Locating Screen ➌ ➍ ➑ ➎Depth and Current Pipe and Cable LocatingSonde Locating Screen ➌ ➐ ➍ ➎Sonde Locating Pin-Pointing the Sonde Transmitter SpecificationsReceiver Environmental Cleaning InstructionsStatement of Intended Use CE ComplianceStatement of Conformity Track and Trace Solutions