AMX MAX Servers manual Admin Menu

Page 63

Replacing HDDs in MAX Servers

Step 1: Identify the Drive That Needs To Be Replaced

To identify the drive that needs to be replaced, access the MAX Admin Menu, via Telnet:

1.Launch WinMAX, open the System Information tab, and verify that you are communicating with the intended HT server by checking the Server IP Address or URL field.

2.Click on the Server Configuration button to open a telnet window. After a brief delay, the system prompts you to log in.

By default, the User Name = ROOT, and the Password = MOZART.

3.Once you have logged in, the Admin Menu is displayed (FIG. 50).

FIG. 50 Admin Menu

4.Select RAID 5 Status. This option displays a listing of HDDs in the HT server. Look for the drive that is labeled as “Degraded”.

The drives on HT Servers are physically labeled with numbers on the front panel. HT04 Servers use drives labeled 1-4, and HT12 Servers use drives 1-12 (see FIG. 51). However, the drives are listed in the RAID 5 Status window (of the Admin Menu) starting with zero (0). Therefore, note that drive “0” in the Raid 5 Status window equates to the drive labeled “1” on the front of the HT server. Remember that each drive number in the Raid 5 Status list is offset by one relative to the labels on the front of the HT server.

Step 2: Physical Removal and Replacement of the Drives

There are two pieces of data that you must provide to complete the process of adding the replacement HDD: The new HDD’s Serial Number, and Key.

The Serial Number is printed on a label placed on the top of the HDD. The Serial Number is located directly beneath the barcode (“S/N WXXXXXXXXXXX”).

The 16-digit Key is printed on a slip of paper included with the HDD.

Be sure to record the Serial Number before inserting the new drive into the server.

1.Lower the faceplate on the front panel of the server. to access the HDDs (FIG. 47).

2.Remove the damaged HDD. Each HDD is mounted in a tray that slides in and out of the server. To remove the drive/tray assembly:

a.Pull the latch forward to unlock the drive tray. Flip the hinged panel out and use it as a handle to gently pull the drive/tray assembly out of its slot.

b.Remove the drive from the drive tray. The drive is secured to the tray with four screws on the bottom panel.

MAX Servers: HT Home Theater and MMS Multimedia Servers

57

 

 

Image 63
Contents MAX Servers AMX Limited Warranty and Disclaimer Table of Contents MAX Admin Menu MAX Servers DVD Drives Supported Formats Rack Mounting HT and MMS-900 Servers MMS Multimedia Servers MAX Servers OverviewMAX HT Home Theater Servers Related DocumentsMAX-HT04/HT12 Home Theater Servers MAX HT Servers Photos and SpecificationsMAX-HT04/HT12 Specifications Product SpecificationsMAX-HT04/HT12 Specifications Page MAX MMS Servers Photos Specifications MMS-01S Multimedia ServerMMS-01S FG MMS-01S FG 2178-10 Product Specifications MMS-02S FG MMS-02S Multimedia ServerMMS-02S FG 2178-12 Product Specifications MMS-02SB FG MMS-02SB Multimedia Server with BackupMMS-02SB FG 2178-11 Product Specifications MMS-04S FG MMS-04S Multimedia ServerMMS-04S FG 2178-07 Product Specifications MMS-12S Multimedia Server MMS-12S FG 2178-08 Product SpecificationsMMS-12S FG 2178-08 Product Specifications OUT MMS-900 Multimedia ServerMMS-900 FG MAX Servers Setup and Configuration Networking Specifications for MAX ServersOverview Online Database If Power Is Removed From the HT ServerMandatory 24-Hour Initialization Period HT Servers only Connect a Mouse, Keyboard and VGA MonitorMMS-900 Servers Connect the Power Cables and Apply PowerMMS-01S, -02S, -02SB and MAX-HT Servers MMS-04S and -12S ServersAdding MAX-AVP Players and/or MAX-AVM Modules Access the MAX Admin MenuWorking With the MAX Admin Menu Add MAX-AVPs and AVM/AOM Modules to the HT ServerAdding MAX-AOM Audio-Only Modules Select Restart MAX daemonConnect the Modules To the MAX Server Connecting MAX-AVPs and/or MAX-AVMsInstall and Configure WinMAX Software Connecting MAX-AOM ModulesIf You Don’t Connect Shutting Down the MAX Server Loading Media Content on the MAX ServerPeriodic Updates DVD and CD PlaybackAccessing the Admin Menu via WinMAX MAX Admin MenuOptions in the MAX Admin Menu include MAX Admin Menu Options OverviewSystem Information MAX Admin Menu System InformationMAX Admin Menu IP Settings IP SettingsPreparing the MAX Server for Receiving Periodic Updates Output Module SetupAdd Output Module Adding New Modules to the SystemRAID 5 Status Viewing all Modules in the SystemRemoving Modules From the System RAID 5 CLI Log Management Specifying Logging LevelsViewing Log Files Deleting Log Files Date, Time LocaleDate, Time, Locale Configure Timezones Setting System Date and TimeModify max.ini ShellAuthenticating a new HDD Authenticate HDDRemoving HDDs From the MAX Server Viewing All HDDs In the MAX ServerOnline Tech Support Parental ControlChange Region Cover ArtUpdate Firmware Changing The Region Code Setting On Your MAX ServerScheduling Automatic Firmware Updates Exit and Disconnect Restart MAX deamonShutdown ExitDVD Regions DVD Region Code SettingsChanging the Region Code Setting on MAX Servers Default Region Code SettingChanging the DVD Region Code Setting On MAX Servers Page MAX Servers DVD Drives Used DVD Drives Compatible FormatsMAX Servers DVD Drives Used DVD Drives Compatible FormatsMDL Series DVD Drives MDL Series PowerFile DVD DrivesReplacing HDDs in MAX Servers Replacing HDDs in MMS ServersIdentify the Drive That Needs To Be Replaced Don’t forget to include the port number Port Rebuild the RAID Array Physical Removal and Replacement of the DrivesOpen a telnet session with the MMS server Authenticate the New HDDMAX-HT12 Server front panel Replacing HDDs in HT ServersAdmin Menu Wxxxxxxxxxxx Add the New Drive to the SystemOptions in the Authenticate HDD menu are described below MAX Admin MenuPage Rack Mounting MAX Servers Included Rack-Mounting Kit Parts Rack Mounting MMS-01S/02S/02SB/04S/12S ServersPrepare the Slide Rail Assemblies Attach the Inner Server Rails to the MMS chassisAttach the Extension Brackets to the Outer Rails Load the MMS Server Into the Rack Intermediate Section Stationary Section Chassis Section Rack Mounting HT and MMS-900 ServersInstall Chassis Sections Onto The Server Chassis Attaching the Chassis Sections to the server chassis Slide Intermediate Sections Into the Stationary SectionsMount the Adapter Bars to the Rack-Rail assemblies Attach the Extension BracketsFront View Rear View Mount the Rail/Bracket Assemblies Into the Equipment RackMounting Rail in equipment rack Adapter Bar Load the HT Server Into the RackSliding the server chassis into the rack Page Page It’s Your World Take Control