AMX MAX Servers manual Rack Mounting HT and MMS-900 Servers

Page 71

Rack Mounting MAX Servers

Inner Server Rail

Outer Slide Rail

Extension Bracket

Rack (front)

FIG. 56 Sliding the MMS server chassis into the rack

Rack Mounting HT and MMS-900 Servers

Each MAX-HT server comes with a Rack-Mounting Kit. Each Rack-Mounting Kit supports one server and includes all hardware required to mount HT servers in a standard 19-inch (48-cm) equipment rack. The parts included in the Kit include:

2 Slide Rail Assemblies (each consists of a Stationary section, an Intermediate section and a Chassis section; pre-assembled for shipping)

2 Extension Brackets

2 End Brackets

6 Locking Plates (4-hole) - not required

4 Adapter Bars (9-hole)

10 flat-head screws, 10 round-head screws

Locking Tab Hole

INTERMEDIATE SECTION (2)

STATIONARY SECTION (2)

CHASSIS SECTION (2)

Locking Release Tab

Extension Brackets (2) End Brackets (2) Locking Plates (6) Adapter Bars (4)

Screws: 10 round head, 10 flat head, 10 locking nuts

FIG. 57 Included Rack Kit Parts

MAX Servers: HT Home Theater and MMS Multimedia Servers

65

 

 

Image 71
Contents MAX Servers AMX Limited Warranty and Disclaimer Table of Contents MAX Admin Menu MAX Servers DVD Drives Supported Formats Rack Mounting HT and MMS-900 Servers MMS Multimedia Servers MAX Servers OverviewMAX HT Home Theater Servers Related DocumentsMAX-HT04/HT12 Home Theater Servers MAX HT Servers Photos and SpecificationsMAX-HT04/HT12 Specifications Product SpecificationsMAX-HT04/HT12 Specifications Page MMS-01S FG MAX MMS Servers Photos SpecificationsMMS-01S Multimedia Server MMS-01S FG 2178-10 Product Specifications MMS-02S FG MMS-02S Multimedia ServerMMS-02S FG 2178-12 Product Specifications MMS-02SB FG MMS-02SB Multimedia Server with BackupMMS-02SB FG 2178-11 Product Specifications MMS-04S FG MMS-04S Multimedia ServerMMS-04S FG 2178-07 Product Specifications MMS-12S Multimedia Server MMS-12S FG 2178-08 Product SpecificationsMMS-12S FG 2178-08 Product Specifications OUT MMS-900 Multimedia ServerMMS-900 FG Overview MAX Servers Setup and ConfigurationNetworking Specifications for MAX Servers Online Database If Power Is Removed From the HT ServerMandatory 24-Hour Initialization Period HT Servers only Connect a Mouse, Keyboard and VGA MonitorMMS-900 Servers Connect the Power Cables and Apply PowerMMS-01S, -02S, -02SB and MAX-HT Servers MMS-04S and -12S ServersAdding MAX-AVP Players and/or MAX-AVM Modules Access the MAX Admin MenuWorking With the MAX Admin Menu Add MAX-AVPs and AVM/AOM Modules to the HT ServerAdding MAX-AOM Audio-Only Modules Select Restart MAX daemonConnect the Modules To the MAX Server Connecting MAX-AVPs and/or MAX-AVMsIf You Don’t Connect Install and Configure WinMAX SoftwareConnecting MAX-AOM Modules Shutting Down the MAX Server Loading Media Content on the MAX ServerPeriodic Updates DVD and CD PlaybackAccessing the Admin Menu via WinMAX MAX Admin MenuOptions in the MAX Admin Menu include MAX Admin Menu Options OverviewSystem Information MAX Admin Menu System InformationMAX Admin Menu IP Settings IP SettingsPreparing the MAX Server for Receiving Periodic Updates Output Module SetupAdd Output Module Adding New Modules to the SystemRemoving Modules From the System RAID 5 StatusViewing all Modules in the System RAID 5 CLI Viewing Log Files Log ManagementSpecifying Logging Levels Deleting Log Files Date, Time LocaleDate, Time, Locale Configure Timezones Setting System Date and TimeModify max.ini ShellAuthenticating a new HDD Authenticate HDDRemoving HDDs From the MAX Server Viewing All HDDs In the MAX ServerOnline Tech Support Parental ControlChange Region Cover ArtScheduling Automatic Firmware Updates Update FirmwareChanging The Region Code Setting On Your MAX Server Exit and Disconnect Restart MAX deamonShutdown ExitDVD Regions DVD Region Code SettingsChanging the Region Code Setting on MAX Servers Default Region Code SettingChanging the DVD Region Code Setting On MAX Servers Page MAX Servers DVD Drives Used DVD Drives Compatible FormatsMAX Servers DVD Drives Used DVD Drives Compatible FormatsMDL Series DVD Drives MDL Series PowerFile DVD DrivesIdentify the Drive That Needs To Be Replaced Replacing HDDs in MAX ServersReplacing HDDs in MMS Servers Don’t forget to include the port number Port Rebuild the RAID Array Physical Removal and Replacement of the DrivesOpen a telnet session with the MMS server Authenticate the New HDDMAX-HT12 Server front panel Replacing HDDs in HT ServersAdmin Menu Wxxxxxxxxxxx Add the New Drive to the SystemOptions in the Authenticate HDD menu are described below MAX Admin MenuPage Rack Mounting MAX Servers Included Rack-Mounting Kit Parts Rack Mounting MMS-01S/02S/02SB/04S/12S ServersAttach the Extension Brackets to the Outer Rails Prepare the Slide Rail AssembliesAttach the Inner Server Rails to the MMS chassis Load the MMS Server Into the Rack Intermediate Section Stationary Section Chassis Section Rack Mounting HT and MMS-900 ServersInstall Chassis Sections Onto The Server Chassis Attaching the Chassis Sections to the server chassis Slide Intermediate Sections Into the Stationary SectionsMount the Adapter Bars to the Rack-Rail assemblies Attach the Extension BracketsFront View Rear View Mount the Rail/Bracket Assemblies Into the Equipment RackMounting Rail in equipment rack Adapter Bar Load the HT Server Into the RackSliding the server chassis into the rack Page Page It’s Your World Take Control