XGA50

1024 x 768

160

1024

24

136

1344

40.30

50.0

54.163

29

768

3

6

806

XGA60

1024 x 768

160

1024

24

136

1344

48.363

60.004

65

29

768

3

6

806

XGA70

1024 x 768

144

1024

24

136

1328

56.476

70.069

75

29

768

3

6

806

XGA75

1024 x 768

176

1024

16

96

1312

60.023

75.029

78.75

28

768

1

3

800

XGA85

1024 x 768

208

1024

48

96

1376

68.677

84.997

94.5

36

768

1

3

808

MAC19

1024 x 768

172

1024

34

96

1328

60.135

74.7

79.86

30

768

4

3

805

SXGA5

1280 x 1024

248

1280

48

112

1688

53.30

50.0

89.97

38

1024

1

3

1066

0

SXGA6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1280 x 1024

248

1280

48

112

1688

63.981

60.02

108

38

1024

1

3

1066

SXGA7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

1280 x 1024

248

1280

16

144

1688

79.976

75.025

135

38

1024

1

3

1066

SEGA6

640 x 480

87

640

43

82

852

31.678

59.770

26.990

33

480

14

3

530

0

15.78

430 x 252

46

430

10

33

519

15.780

60.692

8.190

2

252

2

4

260

Tri-F60

640 x 480

116

640

38

64

858

31.469

59.941

27.000

30

480

9

6

525

480p

720 x 480

56

720

16

64

856

31.542

60.080

27.000

30

480

9

6

525

720p

1280 x 720

270

1024

260

96

1650

45.000

60.000

74.250

20

720

5

5

750

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EDTV

720 x 480

59

720

16

63

858

31.469

59.941

27.000

33

480

6

6

525

Note 1: The clock pulse is made in projection unit automatically. External clock input is not equipped.

Note 2: When 15kHz NTSC/PAL signal is supplied to the RGB input terminal, the Digital Signal Link function is not guaranteed for correct signal transfer.

Note 3: When signal except standard type (for example, played back software with a copy guard or a special effect play of VCR, etc.) is supplied to the RGB input terminal, projection unit may not function properly.

CONNECTION AT A MULTI PROJECTION SYSTEM

Digital Link

OUT

VIDEO

NI

O U T

V I D E O

NI

 

RS232C link

Unit-4

Unit-3

AC INLET

AC INLET

15A 125V/250V AC

15A 125V/250V AC

AC OUTLET

AC OUTLET

AC100V-240V 50/60Hz

AC100V-240V 50/60Hz

UNSWITCHED MAX 10A

UNSWITCHED MAX 10A

This is one of the example of connection for a multi-projection system using four projection units.

In this example, signal sources are supplied from composite video signal to video-card and signal from a PC is connected to each cubes by signal links.

The optional wired remote controller is connected to Unit-1 and all the units could be controlled by the remote control through System Bus-Link when RS232C communication links are daisy

A C ? ?

AC power

Wired remote control

?? ? ? ? ? ? ? ? RGB-1 signal

A C ? ?

chain connected.

The final RS232C output should not return to 1st cube.

R G B ? ? - 1

R G B ? ? - 2

RGB-2 signal

OUT

 

DIGITALSIGNALLINK

NI

 

 

RGB2

 

RGB

INPUT

RGB1

P O W E R

FAN

LAMP

 

O U T

CONTROL

RS-232C

NI

 

 

R E M O T E

O U T

V I D E O

NI

OUT

 

DIGITAL SIGNAL LINK

NI

 

 

RGB2

RGBINPUT

RGB1

P O W E R

FAN

LAMP

 

OUT

C O N T R O L R S - 2 3 2 C

NI

R E M O T E

 

 

 

O U T

 

V I D E O

NI

 

 

When both, RS232C control signal and CT-90000 wired remote control are connected, the remote control has a priority over PC, RS-232C connection thus PC control is not possible.

? ? ? ? ?

Video signal

Unit-1

AC INLET

 

 

15A 125V/250V AC

 

AC OUTLET

 

 

AC100V-240V

50/60Hz

 

UNSWITCHED MAX 10A

 

A C ?

?

AC power

Unit-2

AC INLET 15A 125V/250V AC

AC OUTLET

AC100V-240V 50/60Hz

UNSWITCHED MAX 10A

A C ? ?

AC power source

This can be also possible to link up to 4 sets by separately purchasing 6ft monitor power interconnect cable

MULTIPLE CONNECTION

16

Image 16
Contents P503DL Connection AT a MULTI-PROJECTION SYSTEM··················16 Safety Precaution Safety Precautions for User Equipment Use For servicing, maintenance and inspection Safety Precautions for User Precautions for USE and Maintenance General Descriptions Features Dimensions Function of I/O Panel Function of Power Panel Power Switch and Power IndicatorSpecifications Acceptable Signal Type Acceptable RGB Input Signal Timing Horizontal TimingConnection AT a Multi Projection System SEGA6Screen Lock screws Page HOW to Replace the Lamp DisassembleAIR Filter Cabinet DisassembleLocation of KEY Components and Function Module Control ModuleWiring Between Function Blocks DLP Engine adjustment Light Engine BlockEngine Mount Adjustment Adjustment Electronics Adjustment or Setting Input Signal selection Adjustment parameters This is the general idea of adjustments Multiple Screen Wall system example Magnification Electronic Circuit Explanation P503DL control board LED status Appendix-1FAN NG Overall block diagram Appendix-2 Control via RS-232C Command Protocol list RS-232C pin-connection configurationCS4 VN5 Write When lamp does not light When color becomes strangeWhen picture is strange and totally distorted Appendix-3When color wheel motor needs to replace Parts List CABINET, P503DL Cabinet K