Toshiba P503DL service manual Safety Precaution

Page 3
1500 ohm
10 watt
each exposed metallic part.
Good earth ground such as a water pipe, conduit, etc.
Place this probe on
0.15MFD
AC VOLTMETER

SAFETY PRECAUTION

WARNING: Service should not be attempted by anyone unfamiliar with the necessary precautions on this projector. The following are the necessary precautions to be observed before servicing this chassis.

1.An isolation Transformer should be connected in the power line between the projector and the AC line before any service is performed on the projector.

2.When replacing a chassis in the cabinet, always be certain that all the protective devices are put back in place, such as; non-metallic control knobs, insulating covers, shields, isolation resistor-capacitor network etc.

3.Before returning the set to the customer, always perform an AC leakage current check on the exposed metallic parts of the cabinet, such as terminals, screwheads, metal overlays, control shafts etc. to be sure the set is safe to operate without danger of electrical shock. Plug the AC line cord directly into a AC outlet

(do not use a line isolation transformer during this check). Use an AC voltmeter having 5000-ohm per volt or more sensitivity in the following manner: Connect a 1500-ohm 10W resistor, paralleled by a 0.15-MFD, AC type capacitor, between a known good earth ground (water pipe, conduit, etc.) and the exposed metallic parts, one at a time. Measure the AC

voltage across the combination of 1500-ohm resistor

and 0.15-MFD capacitor. Reverse the AC plug at the AC outlet and repeat AC voltage measurements for

each exposed metallic part. Voltage measured must

not exceed 5.25V(rms). This corresponds to 3.5mA(AC). Any value exceeding this limit constitutes

a potential shock hazard and must be corrected immediately.

PRODUCT SAFETY NOTICE

Many electrical and mechanical parts in this chassis have special safety-related characteristics. These characteristics are often passed unnoticed by a visual inspection and the protection afforded by them cannot necessarily be obtained by using replacement components rated for higher voltage, wattage, etc. Replacement parts which have these special safety characteristics are identified in this manual and its supplements; electrical components having such features are identified by the international hazard symbols on the schematic diagram and the parts list.

Before replacing any of these components, read the parts list in this manual carefully. The use of substitute replacement parts which do not have the same safety characteristics as specified in the parts list may create shock, fire or other hazards.

ULTRAVIOLET DANGER IN SERVICE MODE

Eye damage may result from directly viewing the light produced by the lamp used in this product. Always turn off lamp before opening this cover. Ultraviolet radiation eye protection required during servicing.

3

Image 3
Contents P503DL Connection AT a MULTI-PROJECTION SYSTEM··················16 Safety Precaution Safety Precautions for User Equipment Use For servicing, maintenance and inspection Safety Precautions for User Precautions for USE and Maintenance General Descriptions Features Dimensions Function of I/O Panel Power Switch and Power Indicator Function of Power PanelSpecifications Acceptable Signal Type Horizontal Timing Acceptable RGB Input Signal TimingSEGA6 Connection AT a Multi Projection SystemScreen Lock screws Page Disassemble HOW to Replace the LampCabinet Disassemble AIR FilterControl Module Location of KEY Components and Function ModuleWiring Between Function Blocks Light Engine Block DLP Engine adjustmentEngine Mount Adjustment Adjustment Electronics Adjustment or Setting Input Signal selection Adjustment parameters This is the general idea of adjustments Multiple Screen Wall system example Magnification Electronic Circuit Explanation Appendix-1 P503DL control board LED statusFAN NG Overall block diagram RS-232C pin-connection configuration Appendix-2 Control via RS-232C Command Protocol listCS4 VN5 Write Appendix-3 When lamp does not lightWhen color becomes strange When picture is strange and totally distortedWhen color wheel motor needs to replace CABINET, P503DL Cabinet K Parts List