SETUP
Manual Convergence Adjustment Mode (9 Point Manual Adjustment)
NOTES: 1. Please turn ON your television for at least 20 minutes before using this feature.
2.Auto Adjustment Mode is recommended. If convergence is still not acceptable, use the Manual Adjustment Mode.
3.If Auto Adjust mode is selected or the Magic Focus button is pressed, all manual adjust mode settings will be erased.
Using the Remote Control, select
To Move Adjustment Point
To move the adjustment point cursor using the CURSOR buttons, the Adjustment Cursor must be WHITE. Another way to move the Adjustment Point Cursor is to press the following buttons: [2] up, [4] left, [5] down, [6] right. If you use the number buttons while the adjustment point is WHITE, it will change to RED.
To Change the Color of Adjustment Point
Press the SELECT button repeatedly
To Adjust the Convergence
Move the Adjustment Cursor to the point to be adjusted. Use the CURSOR buttons to match the RED and BLUE colors to GREEN (reference color). Properly aligned, all three colors should appear white.
Video | Setup |
Audio |
| Magic Focus Tune Up |
Aspect |
| Menu Preference |
|
| |
Chan. Manager | Set The Inputs | |
| ||
Locks |
| Set Virtual HD |
| Set Black Side Panel | |
Timers |
| |
| Set Closed Captions | |
|
| |
Setup |
| Set Monitor Out |
|
| |
Move | SEL Sel | Set AV Control |
|
| |
|
| About Your TV |
|
| Move SEL Return |
Adjustment Point
Cursor
Setup
Magic Focus Tune Up
Aligns the Red, Green, and Blue colors to correct for Magnetic Influences.
Adjustment Mode
Auto
9 Point Manual
117 Point Manual
If you want to adjust now Start
Move SEL Return
If convergence is acceptable after Manual Convergence adjustment, press EXIT button to access menu mode.
Setup
Magic Focus Tune Up
Manual Adjust
Please make a selection from the options below
Cancel
Done
Back
Reset
Move SEL Select
Use the CURSOR buttons to highlight your chosen option. Press the SELECT button to select.
Select CANCEL to cancel adjusted data and return to main picture.
Select DONE to save your adjustments and return to main picture.
Select BACK to return to the manual convergence adjustment mode.
Select RESET to recall the factory
57