36 en User interface | Video Recording Manager |
|
|
Connect
Click to connect to the device and to assign it to VSG.
When logon is successful, configure the protocol settings if required.
Skip
Click to activate the configuration settings in the Protocol settings group.
This button does not appear, if you configure a camera that was detected by network scan and
added by clicking . The button appears, if you select a line in the VSG cameras list and click the Add... or the Edit... button.
Protocol settings
Make the desired protocol settings. Note that the available configuration settings change with the selected entry in the Type list.
Type
Note: The available configuration settings change with the selected entry.
Entry in the Type list | Available configuration settings |
|
|
Bosch RCP+ | Video input |
| Select the number of the desired camera if you configure |
| a multichannel device. |
|
|
| Stream |
| Select the number of the stream of the selected camera. |
|
|
| Protocol |
| TCP |
| Used for transmission in the Internet and / or for lossless |
| data transmission. Ensures that no data packet gets lost. |
| Bandwidth requirement can be high. |
| Use if the device is located behind a Firewall. Does not |
| support multicast. |
| UDP |
| Used for connectionless and lightweight data |
| transmission in private networks. Data packets can get |
| lost. Bandwidth requirement can be low. |
| Supports multicast. |
|
|
ONVIF | Stream |
| ONVIF Media Profile |
| Contains advanced settings including a specific camera |
| including amongst others the encoding settings. |
| Video source |
| Contains basic video settings including a specific |
| camera. |
| Corresponds to a physical video input. |
|
|
| Token |
| Select a profile number. If you selected Video source, |
| usually only one entry is available. |
|
|
2012.05 v1 DOC | Software Manual | Bosch Sicherheitssysteme GmbH |