Philips LTC 3963/51 manual Alarm Recording Tape Speed 06~240

Page 52

SETUP (Continued)

SETTING THE ALARM

The ALARM function allows the user to set the recording duration, speed to be recorded and tape recycle for alarm recordings. When a contact clos- ure occurs at the ALARM B IN input, the VCR auto- matically enters the RECORD mode at the pre-pro- grammed ALARM recording speed. (See Alarm In, page 10 for a complete description of the ALARM sequence.) The ALARM recording duration can last according to the set value, or until the contact clos- ure is reopened.

The ALARM recording speed can be pre-pro- grammed to 06~240.

The checking signal is automatically recorded on the tape at the beginning of each ALARM recording. Later, you can easily locate the start of each record- ing by using these signals when watching a re- corded content. See “ALARM INDEX SEARCH” on page 23 for details.

See page 15 if you also want to record the date/time. The TIME/DATE display is set as follows during ALARM display.

ALARM stars () will replace the colons (:).

The recording speed will be changed to 06~240 which was selected at the “SPEED” setting in the ALARM display.

DURATION: User programmable length or time the unit stays in the alarm record mode. (MANUAL, 5 SEC, 15 SEC, 30 SEC, 1 MIN, 3 MIN, 5 MIN, 10 MIN, 30 MIN, 60 MIN or TAPE END)

ALARM RECORDING TAPE SPEED (06~240)

ALARM READY (YES or NO)

ALARM SET

DURAT I ON:

MANUAL

SPEED :

06

ALARM READY : YES

ALARM OUT :

DURAT I ON

RECYCLE

FUNCT I ONS

REW I ND , STOP I F ALARM

ALARM OUT (DURATION or PULSE)

RECYCLE FUNCTIONS

(“REWIND, STOP IF ALARM”, “REWIND, STOP” or “REWIND, RE-REC”)

ALARM Display Format Description

Notes:

When the ALARM recording ends, the VCR will return to the status it was in before the alarm was input.

Select 06 at the “SPEED” setting when the dur- ation is within 30 seconds. If the 18~240 speed is selected, electronic “marks” are not recorded on the tape and alarm index search will not operate.

1.Press the START/STOP button. The duration set- ting flashes on/off.

2.Press the UP or DOWN button until the desired setting appears on the monitor. (MANUAL, 5, 15, 30 SEC, 1, 3, 5, 10, 30, 60MIN, TAPE END)

3.Press the SET button. The record speed setting flashes on/off.

4.Press the UP or DOWN button until the desired setting appears on the monitor. (06~240 HR.)

5.Press the SET button. The alarm ready setting flashes on/off.

6.Press the UP or DOWN button to select the alarm ready function. (YES or NO)

Select “YES” if you want to start alarm record- ing even in the normal record or stop mode. Select “NO” if you do not want alarm recording in the stop mode.

7.Press the SET button. The alarm out setting flashes on/off.

8.Press the UP or DOWN button to select the alarm out function. See “ALARM OUT” on page 10 for details. (DURATION or PULSE)

9.Press the SET button.

The RECYCLE position flashes on/off.

10.Press the UP or DOWN button to select the mode at the end of tape. See “TAPE RECYCLE” on page 21 for details.

11.Press the START/STOP button.

Programming for the ALARM has been com- pleted.

Caution when input to ALARM (A) IN:

The conditions for recording an alarm input to ALARM (A) IN are fixed as follows.

Note: The ALARM READY function can be specified as YES or NO.

[Conditions for recording the input to ALARM (A) IN]

DURATION: MANUAL

MODE: 06

ALARM OUT: DURATION

RECYCLE FUNCTION: REWIND, STOP IF ALARM

19

Image 52
Contents Time-lapse Video Recorder Important Safeguards Service Description InstallationService Centers UnpackingFeatures Contents Precautions Controls and Functions Front Eject Button Reverse Play Button Field Reverse ButtonStill Button Field Advance ButtonDisplay Video External Interface 15-PIN Jack Video OUTAudio Audio OUTVideo Connections Using the 15-PIN AdapterAudio Connections External Connections Time Adjust Camera SW OUTREC Start REC OUTCassette Tapes Setup Setting the Program FunctionsSetting the Time and Date Use the Clock SET display to set the date and timeHalf FullOFF To correct information ExampleVideo Mode AUTO, COLOUR, B/W Selection Menu 1 Format DescriptionAlarm OUT on or OFF Tape END on or OFFTrouble on or OFF No Video on or OFFDuration Manual To recall the Alarm display To reset the Alarm memoryOperation Tape RecordingAuto REC Check ONE Shot RecordingRecycle Alarms Present on Results Recorded Tape Alarm RecordingLock Adjust PlaybackAlarm Index Search Playback in the Field ADVANCE/REVERSE ModesOperating the VCR from a Personal Computer Ascii codeDisplay character code Communication ProtocolFormat of Commands and Status Operating the VCR from a Personal ComputerXvcr ? Symbol Identification Type of code Details of code Problem Guide MonitorSpecifications MaintenanceSome DO’S and DON’TS on Safe USE of Equipment Page LTC 3963/61 FCC & Ices Information A. and Canadian Models OnlySafety Precautions Features Contents Precautions 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Stop Button Fast FORWARD/VISUAL Search Button REC Rear Installation External Connections External Connections TDK Type OFF Time HOUR, MINUTE, Second Date MONTH, DAY, Year  4  To correct information Camera SW 18~, ALL, 06 only Setting the Buzzer Alarm Recording Tape Speed 06~240 Alarm Memory Recall and Reset Operation Alarm Recording Operation PL MON A00 12 00P 06 T L Xver ONE Shot REC Xvcr bbb, s, w, l, v, a One numeral 0~7 Problem Guide Specifications