Linear manual Model BGUS/BGUS-D SG/SG-D Operator Installation Guide, Charger Board Sleep Mode

Page 13

MODEL BGUS/BGUS-DSG/SG-D OPERATOR INSTALLATION GUIDE

BGUS-DSG-D

CHARGER BOARD SLEEP MODE

When primary AC power is not available, the operator will continue to operate in battery only mode if the charger board is set in its RUN mode (see Battery Backup Charger Configuration). Accessories wired into the operator will continue to draw power, even when the operator is not opening or closing the gate. This can dramatically reduce the amount of standby time available from the batteries.

To extend the available standby time, the charger board has a “sleep” mode feature which will turn off power to all controls except for any that are wired according to the schematics below. By removing the black jumper cap JP1 located in the upper right hand corner of the charger board this feature can be enabled. After fifteen minutes of inactivity, all controls except those wired as shown below will turn off. Those wired as shown will continue to have power at all times and will upon activation generate first a “wake” signal that will power all controls back up, and then create either an open signal or single button signal, depending on how the wire jumper shown below is connected.

 

JP1

 

OPEN

JUMPER CAP

WAKE

 

TERMINAL

 

TERMINAL

CHARGER BOARD

 

 

-13-

Image 13
Contents Bgus /BGUS-D SG/SG-D Control Board Adjustments and Accessory Connections InstallationPRE-INSTALLATION Information Safety InformationClass IV Restricted Access Vehicular Gate Operator Class I Residential Vehicular Gate OperatorUSE Copper Wire only Page Page Page Electrical Connection and Adjustments Limit CAM AdjustmentsBeyond Their Normal Range of Motion Or Damage MAY Result Board Control With MotorClose Terminals Function Description of FunctionOpen Direction Current Sense Adjustment Close Direction Current Sense AdjustmentMaximum RUN Timer Adjustment Auto Close Timer AdjustmentSurge Protector Instructions Charger Board Sleep Mode Model BGUS/BGUS-D SG/SG-D Operator Installation GuideControl and Accessory Connection Illustrations Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Operator fails to start HOW to Order Replacement PartsPage Model Bgus Gate ARM Assembly Parts List Mechanical Parts ListLinear Drawing #2700-084 Page Supply other batteries Model BGUS-D Gate ARM Assembly Parts ListPage On 230VAC Models Page Linear supplied some distributors supply other batteries 2700-082 Description 2100-1778 Control Box Wrapper 2500-2293 Brush Replacement General BGUS/BGUS-D SG/SG-D Oper TOR Inst Llation Guide Material Safety Data SheetCopyright 2009 Linear LLC 19/2009 P686