Linear BGUS Board Control With Motor, Beyond Their Normal Range of Motion Or Damage MAY Result

Page 9

MODEL BGUS/BGUS-DSG/SG-D OPERATOR INSTALLATION GUIDE

CONTROL BOARD ADJUSTMENTS

LIMIT SWITCH

L.E.D.s

LIMIT SWITCH

CONNECTOR

TERMINAL STRIP #1

CONNECTOR

3A FUSE

 

 

 

 

Board

 

 

 

 

 

 

Control

DC

 

 

 

with

 

 

 

Board

 

 

 

Motor

 

 

 

 

 

 

 

2A FUSE

TERMINAL STRIP #2

 

 

R2 BRAKE

DIAGNOSTIC

 

CONNECTOR

L.E.D.s

RESISTOR

 

 

NOTE: DO NOT FORCE 270-DEGREE POTENTIOMETERS

BEYOND THEIR NORMAL RANGE OF MOTION

OR DAMAGE MAY RESULT!

Auto Close Timer Adjustment: This 270-degree adjustable potentiometer will signal the operator to close automatically, from the fully open position, provided no open, reversing or obstruction signals are present. The timer is adjustable from 0 to 124 seconds. This feature is turned off or on using dip switch #1.

Maximum Run Timer Adjustment: This 270-degree adjustable potentiometer should be left in the fully clockwise position on all barrier gate operators.

Open Direction Current Sense Adjustment: This multi-turn potentiometer is used to calibrate the built-in current sensing feature for detection of obstructions while running in the open direction.

Close Direction Current Sense Adjustment: This multi-turn potentiometer is used to calibrate the built in current sensing feature for detection of obstructions while running in the closed direction.

Master/Slave Connection Block: This terminal block is used in conjunction with two operators to configure two gates to open and close together.

Dip Switches:

#1 This switch turns the auto close timer off/on.

#2 This switch controls the behavior of the open/reset function in barrier gates only. When the switch is turned ON, a momentary open/ reset pulse will cause the arm to raise and stay raised until a reset or another open/reset signal occures. In the ON position, this switch also disables the counting function of Dip Switch #4. When the switch is turned OFF, the arm will lower as the open/reset signal is no longer present.

#3 This switch is used in conjunction with single-button controls and radio receivers. In the ON position, successive inputs will cause signals in the order of OPEN-STOP-CLOSE-STOP. In the OFF position, inputs will cause an OPEN signal unless the gate is fully open, in which case it will signal CLOSE.

#4 In the OFF position, for every open signal the barrier gate receives, there must be a reset signal before the arm will come down. In the ON position, this feature is disabled.

#5 In the OFF position, if two vehicles are close together and the second vehicle triggers the reset loop as the arm is coming down, the arm will stop until the second car is clear of the loop, then continue down. In the On position, the arm will continue down even when a second car triggers the reset loop. If the application requires that only a single vehicle pass through at a time, then this featurte should be ON. In all other cases the feature should be left OFF, as the arm will come down onto a tailgating vehicle.

#6 In the ON position, this switch will disable the inherent DC brake in DC operators only. In addition, the R2 brake resistor on the DC motor board must be cut from the board (refer to the picture above). In the OFF position, the DC brake will function.

#7 Not used at this time.

#8 This switch is used to set Master/Slave configuration. Operators which are stand-alone or master units should be set to OFF, while only slave units should have this switch set to ON.

-9-

Image 9
Contents Bgus /BGUS-D SG/SG-D Control Board Adjustments and Accessory Connections InstallationPRE-INSTALLATION Information Safety InformationClass IV Restricted Access Vehicular Gate Operator Class I Residential Vehicular Gate OperatorUSE Copper Wire only Page Page Page Electrical Connection and Adjustments Limit CAM AdjustmentsBeyond Their Normal Range of Motion Or Damage MAY Result Board Control With MotorClose Terminals Function Description of FunctionOpen Direction Current Sense Adjustment Close Direction Current Sense AdjustmentMaximum RUN Timer Adjustment Auto Close Timer AdjustmentSurge Protector Instructions Charger Board Sleep Mode Model BGUS/BGUS-D SG/SG-D Operator Installation GuideControl and Accessory Connection Illustrations Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Operator fails to start HOW to Order Replacement PartsPage Mechanical Parts List Model Bgus Gate ARM Assembly Parts ListLinear Drawing #2700-084 Page Supply other batteries Model BGUS-D Gate ARM Assembly Parts ListPage On 230VAC Models Page Linear supplied some distributors supply other batteries 2700-082 Description 2100-1778 Control Box Wrapper 2500-2293 Brush Replacement General BGUS/BGUS-D SG/SG-D Oper TOR Inst Llation Guide Material Safety Data SheetCopyright 2009 Linear LLC 19/2009 P686