CURRENT SENSING ADJUSTMENTS

Because gates vary in construction and may have different force requirements in the open and close directions to move, the LINEAR control board has separate Multi-turn potentiometers for adjusting in both directions independently. The adjustment should be set light enough to maintain minimal force (40 lbs.) should an obstruction occur, but high enough to keep the gate moving under normal conditions without interruption.

Prior to adjusting the operator current sensing functions, make sure the gate moves freely in both directions. A badly aligned or poorly maintained gate may cause false triggering of the current sensor. Refer to Page 9 when following the instructions below. A factory adjustment tool has been supplied to make these adjustments easier. This tool has been taped to the control box for your convenience.

CLOSE DIRECTION CURRENT SENSE ADJUSTMENT

When the gate operator leaves the factory, it has been preset for a relatively light gate function and will require additional adjustment. Begin by starting the gate going closed. If the operator stops and reverses, turn the close direction potentiometer (see Page 9) one turn higher, press the STOP button, and try again. Repeat this process until the gate no longer causes false tripping of the current sensor. Note that each time the gate operator reverses, the STOP button must be pressed. Next, turn the close direction potentiometer lower slowly while the operator is running the gate closed until the gate operator stops and reverses again. From this point, turn the close direction potentiometer higher by 1 1/2 turns for all 115 Volt AC and 24 Volt DC operators, and by 3/4 of a turn higher for all 230 Volt AC operators. Additional fine adjustment by 1/4 turns may be necessary to eliminate false triggering.

OPEN DIRECTION CURRENT SENSE ADJUSTMENT

Repeat the same process with the open direction potentiometer while running the gate in the open direction. Once this is done, run the gate through several complete cycles and make sure the gate does not false trip in either direction.

Multi-turn Potentiometer

Remember it is important not to set the adjustment too high! Doing so will defeat the purpose of the cur- rent sensing as an obstruction detecting feature.

MAXIMUM RUN TIMER ADJUSTMENT

This adjustment is not used in barrier gate operators and should be turned fully clockwise.

AUTO CLOSE TIMER ADJUSTMENT

This adjustable potentiometer sets the length of time which elapses before the gate operator automatically closes the gate, from the fully open position, provided no open, reversing, or obstruction signals are present. This feature can be turned on or off via dip switch selection. See Page 9 for details. Do not use the auto close timer without an appropriate reversing device installed!

MASTER/SLAVE CONNECTION

A three-wire shielded conductor cable is required to connect master and slave operators. You must use Belden 8760 Twisted Pair Shielded Cable (or equivalent) only – LINEAR part number 2500-1982, per foot). See Page 9 for details of this connection, as well as dip switch selection. Note: The SHIELD wire should be connected in both the master and slave operators. In addition, you must run power to both the master and slave operators.

-11-

Image 11
Contents Bgus /BGUS-D SG/SG-D Control Board Adjustments and Accessory Connections InstallationClass I Residential Vehicular Gate Operator Safety InformationPRE-INSTALLATION Information Class IV Restricted Access Vehicular Gate OperatorUSE Copper Wire only Page Page Page Electrical Connection and Adjustments Limit CAM AdjustmentsBeyond Their Normal Range of Motion Or Damage MAY Result Board Control With MotorClose Terminals Function Description of FunctionAuto Close Timer Adjustment Close Direction Current Sense AdjustmentOpen Direction Current Sense Adjustment Maximum RUN Timer AdjustmentSurge Protector Instructions Charger Board Sleep Mode Model BGUS/BGUS-D SG/SG-D Operator Installation GuideControl and Accessory Connection Illustrations Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Model BGUS/BGUS-D SG/SG-D Operator Installation Guide Operator fails to start HOW to Order Replacement PartsPage Linear Drawing #2700-084 Mechanical Parts ListModel Bgus Gate ARM Assembly Parts List Page Supply other batteries Model BGUS-D Gate ARM Assembly Parts ListPage On 230VAC Models Page Linear supplied some distributors supply other batteries 2700-082 Description 2100-1778 Control Box Wrapper 2500-2293 Brush Replacement General BGUS/BGUS-D SG/SG-D Oper TOR Inst Llation Guide Material Safety Data SheetCopyright 2009 Linear LLC 19/2009 P686