WIRING DISTANCE: | D1 | M1 | M2 | PS | M3 | D2 |
|
– |
+ |
12V DC
POWER ONLY
A
Figure 1
B
PS
– |
+ |
12V DC POWER ONLY
Figure 2
WIRING DISTANCE
Wire | Distance(MAX) | ||
A | B | ||
| |||
φ 1.0 mm(18AWG) | 480 m(1575’) | 240 m(780’) |
Dimensions (HxWxD): 180H x 143W x 53.5D (mm).
RESTRICTIONS
·Only one power supply can be used on one system.
·Up to 4 masters can be connected on the multiple masters configuration, or up to 3 masters on the intermix configuration.
·Use the door release button only when the TALK button is not pressed. (Don't operate the door release when talking.) Proper (relay) operation may not be guaranteed under the following conditions.
·When a master is called from another sub or master station while talking (Including when the Call tone is sounding)
·When a master is called from another master while the OCCUPIED lamp is on
6TROUBLESHOOTING GUIDE
ENTRY # | PROBLEM | POSSIBLE CAUSE | SOLUTION |
| |
|
|
|
| ||
| Door station does not call | Missing jumpers | Are there 2 or 3 conductors run to the door station? If 2 wires, jumper must | ||
1 | in (no call tone or LED |
|
| remain attached between E and — at both the door station and the master | |
light). |
|
| station. Replace jumper. In a | E / — jumper | |
|
|
| |||
|
|
|
| should be removed and 3 wires should be connected. |
|
|
|
|
|
| |
| Door station does not call | Missing connection of — | If communication works, check connection between — | terminal of door | |
2 | in (no call tone or LED | terminal. |
| station and master. Test | |
light) |
|
| between # and — terminal of master. If this rings the tone and lights the | ||
|
|
| |||
|
|
|
| light, the — wire from the door station is not connected properly. | |
|
|
|
|
| |
| Door station does not call | 1 and E | Check that the 1 and E wire are not reversed. If they are, communication | ||
3 | in (no call tone or LED | terminals. |
| will work but |
|
| light) |
|
|
|
|
|
|
|
|
| |
| No communication to | E | Communication is between the 1 and E terminal of the door station to a # | ||
4 | door station. | terminal. |
| and E terminal of the master station. If | |
|
|
| continuity. Check the 1 and E wires at the sub to ensure that they are not | ||
|
|
|
| ||
|
|
|
| reversed. |
|
|
|
|
|
|
|
– 11 –