2SYSTEM OUTLINE & COMPONENTS (Cont.)

Call tone adjustment

3-position volume switch, located under Operation plate.

Adjusts call tone volume to low (far left), medium, high (far right).

Selector switch for Call Tone in Occupied Mode

LEF surface mount master stations are set in the "B" position from the factory. This allows a sub call-in tone to be heard at a muted level while the master is in the occupied mode.

“A” position: Mutes call tone at master while system is in occupied mode.

“B” position: Call tone is heard when master is in occupied mode.

*No call tone between masters.

3-pos. call tone vol. switch

CALL

(under Operation plate)

LEF-3L

(FRONT CASE BACK VIEW)

A

 

 

 

B

 

 

 

LEF-3L(when shipped)

Cable requirements

Use multi-conductor cable with an overall shield, non-twisted, 22AWG to 18AWG (0.65mm to 1.0mm), to accommodate the maximum number stations in the system.

Use the gauge specified for the maximum distance between the two farthest stations.

Power supply

The entire LEF system can be powered by one power supply (PS-1225UL/PS-1225S 12VDC 2.5A or PS-1215DIN 12VDC 1.5A), located near the center of the wire run.

For a system including the All Call and Chime with the BG-10C, one PS-1225UL(S) or PS-1215DIN will power the BG- 10C and the LEF system.

– 6 –

Image 6
Contents Precautions Used with LE-D, LE-DA, LE-DL, LS-NVP/C Door StationsSupplement to LEF Instructions 1NAMES & Features FeaturesWire Reference Chart North America only Package contents System Outline & ComponentsSystem outline System Outline & Components Precautions on Installation & WiringBefore Installation LE-D/LE-DA Terminal DefinitionsIntercom Locations WireWiring Method PushPower supply Call tone adjustmentSelector switch for Call Tone in Occupied Mode Cable requirementsMounting Back wiring LE room subsSurface wiring or Desk-top use Operation Panel for LEF-3LLEF-3L, 2 x Door Stations Wiring Diagrams Most Common ApplicationsLEF-3L, 3 x Door Stations LEF-3L, 1 x Door StationWiring Diagrams Multiple Masters for Door Answering LEF-3L System with External Signaling RY-ACOperations & Specifications SpecificationsOperations Wiring Distance Troubleshooting GuideWiring Distance RestrictionsTroubleshooting Guide Warranty