Aiphone manual Wiring Diagrams Most Common Applications, LEF-3L, 3 x Door Stations

Page 8

4WIRING DIAGRAMS - Most Common Applications

1 x LEF-3L, 3 x Door Stations

WIth Selective Door Release

Door #1

LEF-3LLE-D/LE-DA

IMPORTANT: When using selective outputs, a separate relay and power source are required. Do not power external devices off of the system power supply.

Door #2

Door #3

NOTE:

LE-D/LE-DA

LE-D/LE-DA

When running 2 conductors

 

 

 

 

homerun to each sub (single master

 

 

system only), leave jumper attached

 

 

between E & on master and

 

 

door stations. Otherwise, remove

PS-1225/UL/S

1

2

PS-1215DIN

3

 

E

+

+

12V DC

C

R

POWER

Y

ONLY

White

Brown

 

 

Red

 

Orange

1

1

 

 

1

E

E

E

12V DC when "Door release (

)" button is pressed

 

AC Transformer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

RY-PA

Yellow A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

for #1

 

 

RY-PA

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

Yellow A

 

 

 

 

 

 

 

 

A

 

 

 

for #2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Black

RY-PA

Yellow

 

 

 

 

 

 

 

 

 

for #3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

jumpers and use separate wires for

E and terminals.

AContact Rating: AC110V 1A DC24V 1A

2 x LEF-3L, 2 x Door Stations

With Master to Master communication shown on channel 3

With Selective Door Release

 

Door #1

Door #2

 

 

LEF-3L

LEF-3L

LE-D/LE-DA

LE-D/LE-DA

 

1

PS-1225/UL/S

2

3

PS-1215DIN

C

 

E

+

+

12V DC

R

Y

POWER

White

ONLY

Brown

 

 

Red

 

Orange

1

2

C

3

E

+

R

Y

White

Brown

Red

Orange

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RY-PA

 

 

 

 

Black

 

Yellow A

 

for #1

 

 

 

 

 

 

 

 

 

Black

1

EAContact Rating: AC110V 1A

DC24V 1A

 

AC Transformer

RY-PA

A

Yellow

for #2

 

To prevent shorts, be sure to cut unused lead wires at the button and insulate the ends.

2 x LEF-3L, 1 x Door Station

With Master to Master Communication

Door Station wired on each station's own number terminal (different on each master)

LEF-3L

 

C

PS-1225/UL/S

2

3

PS-1215DIN

1

 

E

+

+

12V DC

R

Y

POWER

White

ONLY

Brown

Red

 

 

Orange

LEF-3L

1

C

3

2

E

+

R

Y

White

Red

Brown

Orange

Optional Remote station:

LE-D/LE-DA

 

LS-NVP

LEF-3L

LE-SS

 

 

#

Red

E

Black

-

Green

 

1

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12V DC when "Door release (

)"

 

 

 

 

 

 

 

 

button is pressed

 

 

 

 

 

 

 

 

 

A

 

 

Black

RY-PA

Yellow

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AContact Rating: AC110V 1A

DC24V 1A

AC Transformer

To prevent shorts, be sure to cut unused lead wires at the button and insulate the ends.

– 8 –

Image 8
Contents Supplement to LEF Instructions PrecautionsUsed with LE-D, LE-DA, LE-DL, LS-NVP/C Door Stations Wire Reference Chart North America only 1NAMES & FeaturesFeatures System outline Package contentsSystem Outline & Components Precautions on Installation & Wiring Before InstallationSystem Outline & Components LE-D/LE-DA Terminal DefinitionsWire Wiring MethodIntercom Locations PushCall tone adjustment Selector switch for Call Tone in Occupied ModePower supply Cable requirementsBack wiring LE room subs Surface wiring or Desk-top useMounting Operation Panel for LEF-3LWiring Diagrams Most Common Applications LEF-3L, 3 x Door StationsLEF-3L, 2 x Door Stations LEF-3L, 1 x Door StationWiring Diagrams Multiple Masters for Door Answering LEF-3L System with External Signaling RY-ACOperations Operations & SpecificationsSpecifications Troubleshooting Guide Wiring DistanceWiring Distance RestrictionsTroubleshooting Guide Warranty