Aiphone LEF-3L manual Operations & Specifications

Page 10

5OPERATIONS & SPECIFICATIONS

OPERATIONS:

Calling a master or sub:

1.Depress a station selector button 1 ~ 3.

2.Press the TALK button to speak, and release to listen to the reply.

3.To conclude, depress OFF button.

Receiving a call from a sub station:

1.Sub station calls in with tone and LED, which stays lit for 20 seconds.

2.Depress the lit station selector button.

3.Press the TALK button to speak, and release to listen.

4.Communication at the door station is hands free.

5.Depress OFF button when finished.

Receiving call from another master:

1.When a master calls to another master (without tone & LED), the responding master answers back handsfree.

2.The Occupied lamp will be on while the initiating master has a station selected.

3.Do not press any buttons on the master when responding to another master's call.

Door answering (from a master station only):

1.Audio door station calls in with an electronic call tone & LED, which stays lit for 20 seconds.

2.Depress the lit selector button, then press TALK to speak, release to listen.

Door release with “LOCK” button:

LEF-3L provides selective door release to multiple doors (One RY-PA for each door). When communication is

established to a door station, press the Door release ( ) button to release the corresponding door strike.

Camera Call-up feature:

If the "Camera Call-up" feature is included, the associated relay will provide a maintained closure as long as the station

is selected at the master.

NOTE:

The LEF-3L does not have the "privacy feature", and also cannot send a call tone to another master or remote station in the system.

SPECIFICATIONS:

Power Source:

12V DC at master. Use PS-1225, 1225UL, 1225S (2.5A) or PS-1215 DIN (1.5A). Do not use AC

 

power. Damage to the unit will result.

Current Consumption:

440mA

Communication Output: 800mW @ 20 ohms (receive); 500mW @ 20 ohms (transmit)

Communication:

Push-to-talk, release-to-listen at master station (LEF-3L). Hands free at sub station.

Calling:

Master to sub: By voice

 

Sub to master: Call tone and LED

Wiring:

2 common plus 1 individual per sub, looped; or 3 conductors homerun from each sub.

 

2 conductors homerun from each sub in a single-master system only.

 

Use Aiphone #822202 or #821802 ( 2 cond., 22 or 18AWG), or #822203 (3 cond. 22AWG)

 

12 conductors between master stations. Use Aiphone #822212. (North America only)

 

Shielded cable is strongly recommended.

– 10 –

Image 10
Contents Used with LE-D, LE-DA, LE-DL, LS-NVP/C Door Stations PrecautionsSupplement to LEF Instructions Features 1NAMES & FeaturesWire Reference Chart North America only System Outline & Components Package contentsSystem outline System Outline & Components Precautions on Installation & WiringBefore Installation LE-D/LE-DA Terminal DefinitionsIntercom Locations WireWiring Method PushPower supply Call tone adjustmentSelector switch for Call Tone in Occupied Mode Cable requirementsMounting Back wiring LE room subsSurface wiring or Desk-top use Operation Panel for LEF-3LLEF-3L, 2 x Door Stations Wiring Diagrams Most Common ApplicationsLEF-3L, 3 x Door Stations LEF-3L, 1 x Door StationWiring Diagrams Multiple Masters for Door Answering LEF-3L System with External Signaling RY-ACSpecifications Operations & SpecificationsOperations Wiring Distance Troubleshooting GuideWiring Distance RestrictionsTroubleshooting Guide Warranty