Module Components
Figure 12. P30 Connector
| Table 7. | P30 Connector Pinout | 
 | 
 | ||
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | 
 | Pin | Signal | Pin | Signal | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | A1 | (L) | Logic_GND | A2 (L) | Shelf_GND | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | B1 | (L) | Logic_GND | B2 (L) | +3.3V_MP | 
| 
 | 
 | 
 | 
 | 
 | |
| 
 | C1 (M) | IPMI_Sclk | C2 (M) | IPMI_Sdata | |
| 
 | 
 | 
 | 
 | 
 | |
| 
 | D1 (S | +12V | D2 (S) | +12V | |
| 
 | 
 | 
 | 
 | 
 | 
 | 
| 
 | E1 | (S) | PS1# | E2 (S) | ENABLE# | 
| 
 | 
 | 
 | 
 | 
 | 
 | 
| Table 8. | P30 Signal Descriptions | ||
| 
 | 
 | 
 | 
 | 
| 
 | Pin | Signal | Comments | 
| 
 | 
 | 
 | 
 | 
| 
 | A1 | Logic_GND | Logic ground connection (long contact); provides return path for power and signal | 
| 
 | connections. | ||
| 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
| 
 | A2 | Shelf_GND | Shelf ground connection (long contact); provides safety ground contact between | 
| 
 | SBC and RTM. | ||
| 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
| 
 | B1 | Logic_GND | Logic ground connection (long contact); see above. | 
| 
 | 
 | 
 | 
 | 
| 
 | B2 | +3.3V_MP | Management power (long contact); provides up to 100mA to power management | 
| 
 | system on RTM. Used exclusively for management power. | ||
| 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
| 
 | C1 | IPMI_Sclk | IPMB/I2C clock signal (medium contact) | 
| 
 | C2 | IPMI_Sdata | IPMB/ I2C data signal (medium contact); This signal is connected to the on board | 
| 
 | ADM1026 for temperature and voltage monitoring on the RTM. | ||
| 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
| 
 | D1 | 12V | 12V RTM payload power (short contact); provides up to 420mA to power active | 
| 
 | 
 | 
 | devices (other than management system) on RTM. See additional requirements | 
| 
 | D2 | 12V | |
| 
 | below. | ||
| 
 | 
 | 
 | 
 | 
| 
 | 
 | 
 | Presence Signal, active low (short contact); the RTM connects this signal to | 
| 
 | E1 | PS1# | Logic_GND through a 100 Ohm resistor (to facilitate manufacturing test). The Front | 
| 
 | 
 | 
 | Board reads this signal to understand if an RTM is fully inserted. | 
| 
 | 
 | 
 | 
 | 
| 
 | E2 | ENABLE# | Module enable signal, active low (short contact); the Front Board sets this signal high | 
| 
 | to reset the RMC/RMD. | ||
| 
 | 
 | 
 | |
| 
 | 
 | 
 | 
 | 
| 22 | Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 |