RTM Management Architecture
•RTM Temp2
•RTM Temp3
•RTM Power Status
Table 15. | Sensor Data Record for RTM |
|
|
|
| |
|
|
|
|
|
|
|
| Sensor Name | Description | Lower | Lower Non | Upper Non | Upper |
| Critical | Critical | Critical | Critical | ||
|
|
| ||||
|
|
|
|
|
|
|
| RTM +1.8V | For SAS Retimer | 1.71 | – | – | 1.89 |
|
|
|
|
|
|
|
| RTM +3.3V | For other Integrated Circuits | 3.10 | – | – | 3.47 |
|
|
|
|
|
|
|
| RTM +3.3V SUS | Early voltage for ADM1026 | 3.11 | – | – | 3.46 |
|
|
|
|
|
|
|
| RTM +5.0V | For USB Interface | 4.71 | – | – | 5.23 |
|
|
|
|
|
|
|
| RTM +5V SUS | Early voltage for Hotswap LED | 4.73 | – | – | 5.25 |
|
|
|
|
|
|
|
| RTM +12V | Main voltage rail for other ICs/ | 10.71 | – | – | 13.10 |
|
| peripherals |
|
|
|
|
|
|
|
|
|
|
|
| RTM Temp 1 | Internal ADM1026 (U3) | – | 70 | 75 | |
|
| [see Figure 16 for location] |
|
|
|
|
|
|
|
|
|
|
|
| RTM Temp 2 | External Thermal Diode (Q3) | – | 70 | 75 | |
|
| [see Figure 16 for location] |
|
|
|
|
|
|
|
|
|
|
|
| RTM Temp 3 | External Thermal Diode (Q2) | – | 70 | 75 | |
|
| [see Figure 16 for location] |
|
|
|
|
|
|
|
|
|
|
|
Figure 16. | RTM Temperature Sensor Locations |
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
32 | Intel NetStructure® MPRTM0020 Technical Product Specification – April 2006 |