Bowens BWL-0410 operating instructions Specifications, Unit GMD250 GMD500

Page 10

 

Specifications

 

 

 

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

GMD250

GMD500

 

 

 

 

 

 

 

 

 

 

Part Number

(230V)

BW3700

BW3710

 

 

 

 

(117V)

BW3705

BW3715

 

 

 

 

 

 

 

 

 

 

Stored Energy (max)

 

250Ws

500Ws

 

 

 

 

 

 

 

 

 

 

Sync Voltage

 

5V

5V

 

 

 

 

 

 

 

 

 

Flash Colour Temperature

5600K ±300K

5600K ±300K

 

 

 

 

 

 

 

 

 

 

Circuit Protection

 

230V - 5A (F) (117V - 10A (T))

230V - 5A (F) (117V - 10A (T))

 

 

 

 

 

 

 

 

 

Supply Voltage Range 230V

190-250V AC 50Hz

190-250V AC 50Hz

 

 

 

(117V)

 

(95-130V AC 60Hz)

(95-130V AC 60 Hz)

 

 

 

 

 

 

 

 

 

 

Guide Number

 

56.1

79.8

 

 

 

(Full power, 50° Keylite, ISO 100)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical Recycle Time

0.81 (1.1) secs

1.54 (1.95) secs

 

 

 

Full Power, 230V, 50Hz (117V 60Hz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Modelling Power Control

Full / Intermittent / Off

Full / Intermittent / Off

 

 

 

 

 

 

 

 

 

Flash Duration (t=0.5)

1/1315

1/925

 

 

 

(Full power)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flash Power Control

 

Full to 1/32 5 stops

Full to 1/32 5 Stops

 

 

 

 

 

 

 

 

 

 

Modelling Lamp

 

Max 275W

Max 275W

 

 

 

 

 

 

 

 

 

 

Ready Indication

 

100%

100%

 

 

 

 

 

 

 

 

 

 

User Replaceable Flash Tube

Clear = BW2030

Clear = BW2030

 

 

 

UV = BW2032

UV = BW2032

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Photocell

 

On/Off

On/Off

 

 

 

 

 

 

 

 

 

 

Audio Ready Signal

 

On/Off

On/Off

 

 

 

 

 

 

 

 

 

Recommended Modelling

275W Photoflood

275W Photoflood

 

 

 

Lamps

 

250W Halostar

250W Halostar

 

 

 

 

 

 

 

 

 

 

Weight

 

2.9Kg

3.4Kg

 

 

 

 

 

 

 

 

 

Dimensions (l x w x h)

365 x 145 x 130mm

365 x 145 x 130mm

 

 

 

 

 

 

 

 

Due to our policy of constant product improvement,

Bowens International reserves the right to change equipment

 

specifications at any time and without notice.

 

 

18

www.bowens.co.uk

www.bowens.co.uk

19

 

 

 

 

Image 10
Contents Operating Instructions Safety Notes Table of ContentsIntroduction Side Control Panel MountingFitting / Removing Reflectors Flash Power ControlFitting the Modelling Lamp FuseNormal Functions Function Display DescriptionAdvanced Functions Functions Menu SystemPhotocell Modelling Lamp Ready IndicatorInformation & Error Codes Audible Ready BeepAdditional Information Flashtube ReplacementBattery Power Pulsar Radio TriggerAccessories Pulsar Clip-On PlatformSpecifications Unit GMD250 GMD500