Functions Overview

During normal use simply rotate the dial to adjust the power to the required level. The unit ready indication is by means of a ʻsteadyʼ display and a sounder beep (if on) as well as the modelling lamp indication function when the unit reaches ready (if switched on). While changing the power level the display flashes at different rates to indicate whether the unit is charging or if there is excess power that needs dumping. The display will flash ʻquicklyʼ while the unit is charging and flash ʻslowlyʼ to indicate that there is excess power that needs to be dumped. To test the flash and/or dump any excess power press the ʻTESTʼ button.

The unit can be triggered via the ʻsync socketʼ connected to the relevant system or via the ʻPhotocellʼ as required. Other displays may occur during operation to provide warnings of problems or to indicate the unit status.

To change any of the unitʼs settings first press the ʻMENUʼ button on the side of the unit; ʻSETʼ will be displayed briefly showing that the unit is entering the user setup options followed by ʻLPʼ (for ʻLamp settingsʼ) as the first item. Each press of the ʻMENUʼ button takes you down one level of the menu structure until you cannot go any further; at this point the sounder (if switched on) will provide a warning beep.

At any menu level turning the rotary control will either select another function/option or change the setting of the chosen function. Each press of the ʻDONEʼ button takes you up one level until you exit the user setup mode, at which point ʻEndʼ is displayed. Any altered user setting will be saved to the units memory. See below illustration for example of how to change the Modelling Lamp settings to off.

 

 

 

Normal Functions

 

 

 

 

 

 

 

 

 

 

 

Function

Display

Description

 

 

 

 

 

 

 

 

 

*Lamp

LP

Off (OFF) - Lamp remains ʻoffʼ during operation.

 

 

 

USER (USR) - In ʻuserʼ mode the modelling lamp

 

 

 

can be adjusted from f5.0 to f10.0

 

 

 

Proportional (PRO) - In ʻproportionalʼ mode

 

 

 

the modelling lamp will automatically adjust itself

 

 

 

to the same output level as the flash.

 

 

 

Full (FUL) - When the modelling lamp is set

 

 

 

to ʻfullʼ the power output will remain at the

 

 

 

maximum level.

 

 

*Lamp Ready

IND

Off (OFF) - No lamp ready indication.

 

Indication

 

 

 

Intermittent (INT) - If modelling lamp is on it goes

 

 

 

off after the unit has fired and comes back on at

 

 

 

the set level once the unit has recharged.

 

 

 

Pulse (PUL) - Modelling lamp pulses when the

 

 

 

unit has recharged after firing.

Example Illustration: How to change the Modelling Lamp to off.

Step One.

During normal operation press the MENU button to enter the normal functions menu.

Step Two.

Next, turn the rotary dial to scroll through the normal functions.

Step Three.

Once the desired setting is shown press the MENU button again to enter the available functions for that particular setting.

Step Four.

Next turn the rotary dial again to find the desired option of the setting you wish to change.

Step Five.

Scroll through the available options until the desired setting is shown.

Step Six.

Next press the TEST/DONE button to confirm your selection and go up one menu level. Repeat as necessary with other functions. Finally press TEST/DONE until END is displayed.

Ready Sounder

SND

Off (OFF) - The Ready Sounder beep

 

 

remains off and does not indicate when

 

 

the unit has charged.

 

 

Intermittent (INT) - The unit emits a short beep

 

 

when it has fully recharged to indicate

 

 

that it is ready to fire again.

 

 

Continuous (CON) - The unit emits a continuous

 

 

beep while it is recharging and stops once

 

 

fully recharged.

 

 

 

Photocell

PHO

Off (OFF) - Photocell remains ʻoffʼ.

 

 

1st (1st) - Photocell is set to trigger unit on

 

 

the first flash detected.

 

 

2nd (2nd) - Photocell is set to trigger on

 

 

the second flash detected.

 

 

3rd (3rd) - Photocell is set to trigger on

 

 

the third flash detected.

 

 

4th (4th) - Photocell is set to trigger on

 

 

the fourth flash detected.

8www.bowens.co.uk

* Only available when operating from mains power.

www.bowens.co.uk

9

Image 5
Contents Operating Instructions Introduction Table of ContentsSafety Notes Mounting Side Control PanelFitting the Modelling Lamp Flash Power ControlFitting / Removing Reflectors FuseFunction Display Description Normal FunctionsFunctions Menu System Advanced FunctionsInformation & Error Codes Modelling Lamp Ready IndicatorPhotocell Audible Ready BeepBattery Power Flashtube ReplacementAdditional Information Pulsar Radio TriggerPulsar Clip-On Platform AccessoriesUnit GMD250 GMD500 Specifications