NOTE: Programming preset 90 (23) disables the manual limit stops until preset 91 (24) is set.

Park – The dome moves to preset 1 when the power-up sequence finishes. The only text on the screen is the preset label (if any).

Scan Auto – The dome initiates scan mode when the power-up sequence finishes. Again, there is no text.

Scan Frame – The dome initiates a frame scan when the power-up sequence finishes.

Scan Rand – The dome initiates a random scan when the power-up sequence finishes. The default setting is Default. To select the power-up mode:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Power Up Mode.

2.Press the Iris Open button to enter the Power Up Mode submenu.

3.Move the joystick up or down to cycle through the selections. Stop on the item you want to select.

4.SELECT – Press the Iris Open button to select your choice.

CANCEL – Press the Iris Close button if you do not want to change the setting.

AUTO FLIP

The two auto flip modes are on (auto flip enabled) or off (feature disabled). To change the auto flip mode:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Other.

2.Press the Iris Open button to enter the Other submenu.

3.Move the joystick up or down to position the cursor beside Auto Flip.

4.Press the Iris Open button. The cursor moves to the right beside the word On or Off.

5.Move the joystick up or down to toggle between On and Off.

6.SELECT – Press the Iris Open button to select your choice.

CANCEL – Press the Iris Close button if you do not want to change the setting.

LIMIT STOPS

The two types of limit stop are manual and scan. When manual limit stops are set, a manual (joystick) pan operation stops when a limit is reached. When scan limit stops are set, the dome reverses direction during random, frame, and auto scanning when a limit stop is reached. Software controls limit stops. To set limit stops:

1.Turn on limit stop mode.

2.Program the limit stops.

Turning Limit Stops On or Off

To change the limit stop mode:

1.On the main menu, move the joystick up or down to position the cursor (>) beside Other.

2.Press the Iris Open button to enter the Other submenu.

3.Move the joystick up or down to position the cursor beside Limit Stops.

4.Press the Iris Open button. The cursor moves to the right beside the word On or Off.

5.Move the joystick up or down to toggle between On and Off.

6.SELECT – Press the Iris Open button to select your choice.

CANCEL– Press the Iris Close button if you do not want to change the setting.

Programming Limit Stops

MANUAL LIMIT STOPS

Refer to the documentation for your control system for programming presets, then do the following:

1.Make sure limit stops are turned ON (refer to the Limit Stops section), then exit the menu.

2.Push the joystick left until you reach the limit you want the camera to go to on the left.

3.Program preset 90 (23).

4.Push the stick right to the limit you want the camera to go to on the right.

5.Program preset 91 (24).

Setting presets 90 (23) and 91 (24) to the same point disables manual limit stops.

16

Pelco Manual C1498M-A (7/99)

Image 16
Contents Listed Contents Important Safeguards and Warnings InstallationDescription ModelsTable B. Switch Settings for SW2 P-Type Control Table C. Switch Settings for SW2 D-Type Control OFF 113 169 POWER-UP Display OperationPreset Functions PAN and Tilt FunctionsAuto Flip Scan SpeedPark Main Menu AccessProgramming the Spectra Lite Reset Camera Backlight CompensationCM9750 CM9760GAIN/AGC Auto IrisShutter Speed Sharpness POWER-UP ModeWhite Balance Limit Stops Manual Limit StopsTroubleshooting Symptom Unit or fan does not operatePark Time Minutes Scan Limit StopsBack BOX Electronic Assembly Removal Mechanical SpecificationsCamera Regulatory Notices Warranty and Return InformationRevision History