Pelco C1498M-A operation manual Table B. Switch Settings for SW2 P-Type Control

Page 4

CAUTION: Make sure the dome drive locks into

place. Pull down on the dome drive with moderate pressure to ensure that it stays in place.

Baud

Switch Setting

Rate

SW2-6 SW2-7 SW2-8

 

 

 

 

2400

OFF

OFF

OFF

4800

ON

OFF

OFF

9600

OFF

ON

OFF

 

 

 

 

2.Set the switches on the bottom of the dome drive. Refer to Table A for the settings for SW1, and Table B and Table C for SW2.

3.Install the dome drive in the back box. Line up the green tab and red tab on the dome drive with the green label and red label on the back box. Raise the dome drive into the back box and push on the ends of the tabs until they both click into place on the back box.

4.Turn on power, if it is not on. Listen for the fan operating. If the fan does not work, the dome will overheat and shut down. If the fan does not work, return the back box electronic assembly and dome drive to the factory for repair. Refer to the Back Box Electronic Assembly Removal section in manual C1487M-C.

Table A. Switch Settings for SW1

Control Type

 

 

 

Switch Setting

 

 

 

 

SW1-1

SW1-2

SW1-3

SW1-4 SW1-5

SW1-6 SW1-7 SW1-8

 

 

 

 

 

 

 

 

 

Coaxitron®

OFF

OFF

OFF

OFF

OFF

OFF

OFF

OFF**

P-Type Control

ON

OFF

OFF

OFF

OFF

OFF

OFF

OFF**

D-Type Control

OFF

ON

OFF

OFF

OFF

OFF

OFF*

OFF**

NOTES: Switches SW1-3 through SW1-6 MUST be OFF.

D-type control is RS-422 that is compatible with Pelco‘s CM6700, MPT9500 and CM8500 controllers or with American Dynamics control systems using the AD2083 Translator.

P-type control is RS-422 that is compatible with Pelco's CM6700/CM9750/CM9760 control systems.

*OFF - Use with controllers that have more than 32 presets. ON - Use with American Dynamics controllers (32 presets).

**OFF - Use with all control systems except CM9502 with variable speed keyboards. For CM9502 with fixed speed keyboards, set switch OFF.

ON - Use with CM9502 with variable speed keyboards for smoother joystick control.

Table B. Switch Settings for SW2 – P-Type Control

NOTE: For Coaxitron® controls, all switches on SW2 MUST be OFF. For D-type control systems, refer to Table C.

Receiver Address

 

 

Switch Setting

 

 

 

SW2-1

SW2-2

SW2-3

SW2-4

SW2-5

 

 

 

 

 

 

1

OFF

OFF

OFF

OFF

OFF

2

ON

OFF

OFF

OFF

OFF

3

OFF

ON

OFF

OFF

OFF

4

ON

ON

OFF

OFF

OFF

5

OFF

OFF

ON

OFF

OFF

6

ON

OFF

ON

OFF

OFF

7

OFF

ON

ON

OFF

OFF

8

ON

ON

ON

OFF

OFF

9

OFF

OFF

OFF

ON

OFF

10

ON

OFF

OFF

ON

OFF

11

OFF

ON

OFF

ON

OFF

12

ON

ON

OFF

ON

OFF

13

OFF

OFF

ON

ON

OFF

14

ON

OFF

ON

ON

OFF

15

OFF

ON

ON

ON

OFF

16

ON

ON

ON

ON

OFF

17

OFF

OFF

OFF

OFF

ON

18

ON

OFF

OFF

OFF

ON

19

OFF

ON

OFF

OFF

ON

20

ON

ON

OFF

OFF

ON

21

OFF

OFF

ON

OFF

ON

22

ON

OFF

ON

OFF

ON

23

OFF

ON

ON

OFF

ON

24

ON

ON

ON

OFF

ON

25

OFF

OFF

OFF

ON

ON

26

ON

OFF

OFF

ON

ON

27

OFF

ON

OFF

ON

ON

28

ON

ON

OFF

ON

ON

29

OFF

OFF

ON

ON

ON

30

ON

OFF

ON

ON

ON

31

OFF

ON

ON

ON

ON

32

ON

ON

ON

ON

ON

4

Pelco Manual C1498M-A (7/99)

Image 4
Contents Listed Contents Important Safeguards and Warnings InstallationDescription ModelsTable B. Switch Settings for SW2 P-Type Control Table C. Switch Settings for SW2 D-Type Control OFF 113 169 POWER-UP Display OperationPreset Functions PAN and Tilt FunctionsAuto Flip Scan SpeedPark Main Menu AccessProgramming the Spectra Lite Reset Camera Backlight CompensationCM9750 CM9760GAIN/AGC Auto IrisShutter Speed Sharpness POWER-UP ModeWhite Balance Limit Stops Manual Limit StopsTroubleshooting Symptom Unit or fan does not operatePark Time Minutes Scan Limit StopsBack BOX Electronic Assembly Removal Mechanical SpecificationsCamera Regulatory Notices Warranty and Return InformationRevision History