SECTION 1: SPECIFICATION INFORMATION
|
| OPERATING CAPACITIES | |
OPERATING CAPACITY (PER HOUR): |
| ||
Model | Racks | Dishes | Glasses |
300X | 57 | 1425 | 1425 |
300XN | 57 | 1425 | 1425 |
300XLT | 57 | 1425 | 1425 |
OPERATING CYCLE (SECONDS): |
|
| |
Wash Time |
|
| 45 sec |
Rinse Time |
|
| 11 sec |
Complete Cycle Time |
| 58 sec | |
OPERATING TEMPERATURES (°F): |
| ||
Wash Temperature (Minimum) |
| 150°F | |
Wash Temperature (Minimum) |
| 66°C | |
Rinse Temperature (Minimum) |
| 180°F | |
Rinse Temperature (Minimum) |
| 83°C | |
WATER REQUIREMENTS: |
|
| |
Inlet Temperature (300X/12KW Heater) (Minimum) | 140°F | ||
Inlet Temperature (300X/12KW Heater) (Minimum) | 60°C | ||
Inlet Temperature (300X/14KW Heater) (Minimum) | 110°F | ||
Inlet Temperature (300X/14KW Heater) (Minimum) | 44°C | ||
Inlet Temperature (300XN) (Minimum) | 180°F | ||
Inlet Temperature (300XN) (Minimum) | 83°C | ||
Inlet Temperature (300XLT) (Minimum) | 110°F | ||
Inlet Temperature (300XLT) (Minimum) | 44°C | ||
Gallons per Hour (Approximate) |
| 52 | |
Water Line Size |
|
| 1/2” NPT |
Drain Line Size |
|
| |
Flow Pressure PSI |
| 20 A 5 | |
Wash Tank Capacity (Gallons) |
| 8 | |
Wash Tank Capacity (Liters) |
| 30.3 | |
Rinse Tank Capacity (Gallons)(300X Only) | 3 | ||
Rinse Tank Capacity (Gallons)(300X Only) | 11.4 | ||
STEAM REQUIREMENTS: |
|
| |
COIL SIZE |
|
| 3/4” |
STEAM FLOW PRESSURE (P.S.I.) |
| ||
CONSUMPTION @ 15 P.S.I. (LBS/HR) | 45 |
NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.
300X Series Technical Manual
Issued:
2