Jackson 300XS Specification Information, Operating Capacities, Operating Capacity Per Hour

Models: 300X 300XN 300XLT 300XS

1 69
Download 69 pages 13.63 Kb
Page 7
Image 7
SECTION 1: SPECIFICATION INFORMATION

SECTION 1: SPECIFICATION INFORMATION

 

 

OPERATING CAPACITIES

OPERATING CAPACITY (PER HOUR):

 

Model

Racks

Dishes

Glasses

300X

57

1425

1425

300XN

57

1425

1425

300XLT

57

1425

1425

OPERATING CYCLE (SECONDS):

 

 

Wash Time

 

 

45 sec

Rinse Time

 

 

11 sec

Complete Cycle Time

 

58 sec

OPERATING TEMPERATURES (°F):

 

Wash Temperature (Minimum)

 

150°F

Wash Temperature (Minimum)

 

66°C

Rinse Temperature (Minimum)

 

180°F

Rinse Temperature (Minimum)

 

83°C

WATER REQUIREMENTS:

 

 

Inlet Temperature (300X/12KW Heater) (Minimum)

140°F

Inlet Temperature (300X/12KW Heater) (Minimum)

60°C

Inlet Temperature (300X/14KW Heater) (Minimum)

110°F

Inlet Temperature (300X/14KW Heater) (Minimum)

44°C

Inlet Temperature (300XN) (Minimum)

180°F

Inlet Temperature (300XN) (Minimum)

83°C

Inlet Temperature (300XLT) (Minimum)

110°F

Inlet Temperature (300XLT) (Minimum)

44°C

Gallons per Hour (Approximate)

 

52

Water Line Size

 

 

1/2” NPT

Drain Line Size

 

 

1-1/2” NPT

Flow Pressure PSI

 

20 A 5

Wash Tank Capacity (Gallons)

 

8

Wash Tank Capacity (Liters)

 

30.3

Rinse Tank Capacity (Gallons)(300X Only)

3

Rinse Tank Capacity (Gallons)(300X Only)

11.4

STEAM REQUIREMENTS:

 

 

COIL SIZE

 

 

3/4”

STEAM FLOW PRESSURE (P.S.I.)

 

10-20

CONSUMPTION @ 15 P.S.I. (LBS/HR)

45

NOTE: Always refer to the machine data plate for specific electrical and water requirements. The material provided on this page is for reference only and may be subject to change without notice.