Jackson 300XS To Dishmachine Drain, Drain Quench Assembly, To Cold Water Supply, Parts Section

Models: 300X 300XN 300XLT 300XS

1 69
Download 69 pages 13.63 Kb
Page 64
Image 64
Elbow, 1-1/2” 90B Street 04730-206-32-00

SECTION 6: PARTS SECTION

Elbow, 1-1/2” 90B Street 04730-206-32-00

Nipple, 1-1/2” NPT 04730-207-40-00

Modified Compression

Fitting

05700-001-16-52

Reducer, 1-1/2” x 1/4” 04730-002-55-76

To Dishmachine Drain

Tee, 1-1/2” x 1-1/2” x 1-1/2” 04730-011-69-93

Reducer, 1-1/2” to 1/2” 04730-002-55-75

DRAIN QUENCH ASSEMBLY

Drain Quench

Assembly

06401-002-59-52

Lid, Drain Quench

To Dishmachine Drain 05700-002-67-16

Thermostat 05930-003-13-65

Solenoid Valve 04810-100-09-18

DRAIN QUENCH ASSEMBLY To Cold Water SupplyNipple, Close, 1/2” NPTManual background To Cold Water Supply

Box, Drain Quench 05700-002-69-96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Valve, Check, 1/2”

 

 

 

 

 

 

 

 

(Not Shown)

Nipple, Close, 1/2” NPT

04820-002-55-77

(Not Shown)

 

04730-207-15-00

 

From the existing drain, attach the two additional Tees using the 1-1/2” NPT Close Nipples. Tighten the Reducers into the Tees as shown above. Attach the Modified Compression Fitting into the 1-1/2” to 1/4” Reducer. Position the bulb of the thermostat so that it rests approximately 1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks.

300X Series Technical Manual 7610-002-64-22

Issued: 07-26-2006 Revised: N/A

59

Page 64
Image 64
Jackson 300XS To Dishmachine Drain, Drain Quench Assembly, To Cold Water Supply, Parts Section, Elbow, 1-1/2” 90B Street