SECTION 5: SERVICE PROCEDURES

RINSE REGULATING THERMOSTAT REPLACEMENT

Many dishmachines comes with integral booster tanks to ensure proper temperature of the final rinse. Jackson has predominantly used two manufacturers of thermostats, EGO and Stemco. These instructions are for use with kit 06401-003-13-94, which is to replace an EGO rinse regulating thermostat with a Stemco brand.

Jackson offers all of the repair parts necessary for performing this task.

The instructions provided here are for maintenance personnel only. Unauthorized persons should not attempt any of the steps contained in these instructions.

Warning: many of the instructions and steps within this document require the use of tools. Only autho- rized personnel should ever perform any maintenance procedure on the dishmachine!

PREPARATION

1.Power must be secured to the unit at the service breaker. Tag or lock out the service breaker to prevent acci- dental or unauthorized energizing of the machine.

2.Ensure that incoming water to the machine is secured either by use of a shut-off valve or disconnecting the incoming water line.

3.The unit must be drained completely with the drain stopper removed (if applicable).

4.Remove any and all access covers.

TOOLS REQUIRED

The following tools may be needed to perform this maintenance evolution:

1.3/8” Nutdriver

2.7/16” Combination Wrench

3.Needlenose Pliers

4.Phillipshead Screwdriver

5.Flathead Screwdriver

6.Ratchet with 1/2” Socket

TIME REQUIRED

It is estimated that it will take (1) person sixty minutes to perform this task, not including all of the items indicated in the section entitled “PREPARATION”.

IMPORTANT NOTES

1.Read these instructions thoroughly before attempting this maintenance task. Become familiar with the parts and what actions need to be taken. This will save time in the long run!

2.These instructions are shown using a Tempstar model dishmachine. However the steps provided should work for models such as the JP-24 as well.

STEPS

1.Some models, such as the Tempstar pictured below, will require that the thermostat bracket removed from the heater. Using a ratchet, extension and 1/2” socket, remove the nuts and lock washer holding the bracket on.

Removing the thermostat bracket/heater nuts.

Removing the thermostat bracket.

2.With the thermostat and thermostat bracket safely out of the way, use a 7/16” combination wrench to loosen and then remove the imperial brass fitting holding the probe in.

3.Remove the wires from the old thermostat. It may be nec- essary to use the needlenose pliers to accomplish this.

4.Remove the thermostat bracket mounting nuts with the 7/16” nutdriver.

300X Series Technical Manual 7610-002-64-22

Issued: 07-26-2006 Revised: N/A

28

Page 33
Image 33
Jackson 300XLT, 300XS, 300XN technical manual Preparation, Rinse Regulating Thermostat Replacement

300X, 300XN, 300XLT, 300XS specifications

The Jackson 300 series presents a range of advanced air conditioning units that cater to diverse heating and cooling needs. Notable models include the 300X, 300XLT, 300XN, and 300XS, each equipped with distinct features that enhance performance, efficiency, and user comfort.

The Jackson 300X stands out with its cutting-edge inverter technology, which enables precise temperature control while minimizing energy consumption. Its variable-speed compressor adjusts to real-time conditions, ensuring consistent comfort and significant savings on utility bills. The model is also recognized for its robust build quality, designed to withstand extreme weather conditions.

On the other hand, the 300XLT model takes energy efficiency to the next level. This unit incorporates a high-efficiency condenser and evaporator coils, promoting improved heat exchange and reduced energy loss. Additionally, it utilizes eco-friendly refrigerants that comply with environmental regulations, making it a responsible choice for conscious consumers.

The 300XN variant is tailored for noise-sensitive environments, such as bedrooms and offices. This silent operation feature allows the unit to run at remarkably low decibel levels, providing comfort without the disruption of loud HVAC systems. The 300XN also boasts an advanced filtration system that improves indoor air quality, capturing dust and allergens effectively.

Lastly, the Jackson 300XS is designed for exceptional versatility. This model offers multiple installation options, making it suitable for various spaces, from residential to commercial settings. Equipped with smart connectivity features, the 300XS can be controlled remotely via a smartphone app, allowing users to adjust settings on-the-go.

All models come with a user-friendly interface, allowing for easy temperature adjustments and filter change notifications. The durability of these units is further enhanced by their corrosion-resistant materials, extending their lifespan and performance.

In summary, the Jackson 300 series features models like the 300X, 300XLT, 300XN, and 300XS, each offering unique advantages. With a blend of innovative technologies, energy efficiency, and user-friendly controls, these air conditioning units provide tailored solutions to meet varied environmental demands, ensuring optimal comfort year-round. Whether for residential or commercial use, Jackson's offerings underscore a commitment to quality and performance, making them a notable choice in today’s HVAC market.