Pelco IS310-DW, IS310-CW, IS310-CH manual Adjust Enclosure, Adjusting Enclosure Position

Page 8

ADJUST ENCLOSURE

1.Turn on power to the camera and monitor.

2.Release one or both locking rings, and swivel the enclosure until the angle of the camera is correct (refer to Figure 7).

3.Tighten the locking rings.

LOCKING RINGS

Figure 7. Adjusting Enclosure Position

4. If you have a varifocal lens, remove the cover with the supplied 1/8-inch hollow screwdriver bit.

WARNING: Heater elements could be hot! When camera power is on, use caution when adjusting the camera. This applies to all models.

5.Loosen the focal length and focus locking screws (refer to Figure 8), and then adjust the lens according to the scene detail.

VARIFOCAL LENS

LOCKING

SCREWS

Figure 8. Varifocal Locking Screws

6.Retighten the screws.

7.Reseat the O-ring on the cover and reinstall the cover.

8

C3429M-A (1/08)

Image 8 Contents
IS310 Series Camclosure Important Safety Instructions Regulatory Notices Parts List DescriptionInstallation Prepare Wall or CeilingConnect Video and Power Mounting to a 2-gang electrical boxAttach Base Exploded Parts ViewAdjust Enclosure Adjusting Enclosure PositionDN/CH Series Adjustments SW4-1 Auto Gain ControlSW4-2 Backlight Compensation SW4-3 Line SyncSW4-5 Auto White Balance/Manual White Balance SW4-6 ReservedBlemish Detection DAY/NIGHT Operation DW/CW Series Wide Dynamic Range Adjustments SW1-1 Video FormatSW1-2 Line Sync SW1-3 Interlaced Scanning/Progressive ScanningSW1-4 Auto White Balance/Manual White Balance SW1-5 Fluorescent/GeneralSW1-6 General Maximum Wide Dynamic Range SW1-7 Digital Slow ShutterDark on Dusk OFF Color to B-W Auto Iris Level Adjustment Service Connector Attaching the 2.5 mm Monaural Headphone PlugSpecifications GeneralProduct Warranty and Return Information ISO9001
Related manuals
Manual 20 pages 45.2 Kb