Pelco IXE manual Custom Configuration

Page 40

CUSTOM CONFIGURATION

The camera features dual video streams with programmable settings for compression, resolution, image rate, and bit rate. The default names for the streams are Primary and Secondary. Although each stream can be programmed independently, the settings of one stream can limit the options available for the other stream depending on the processing power used.

Figure 30. Custom Video Stream Configuration Page

NOTE: Always configure the Primary stream settings before configuring the Secondary stream. The Primary stream should always be the most resource-intensive of the streams.

To configure custom stream settings:

1.Click the Video Streams tab, and then select Custom Configuration from the drop-down menu.

2.Click both of the Clear buttons to delete the primary and secondary streams settings.

3.Under Primary Stream, type a user-friendly name into the Name box (2 to 64 characters). A user-friendly name makes it easier to recognize the stream (for example, Live and Recording). The Name field is an optional setting.

4.Select the Compression Standard, Resolution, Image Rate, and Bit Rate for the stream.

NOTE: The Compression standard, resolution, image rate, and bit rate settings are dependent on each other. Decide which setting is the main priority before configuring a stream. For example, if you want an image rate of 30 ips, set the image rate before the compression standard and resolution settings.

5.If required adjust the other settings for the compressions standard (refer to Compression Standards on page 41).

6.Repeat steps 3 to 5 for the Secondary stream.

7.Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it.

40

C2953M-A (5/09)

Image 40
Contents IXE Series Extended Platform Network Camera Page Contents Help Menu Log Off Menu Specifications List of Illustrations Regulatory Notices Radio and Television InterferenceOpen Source Software Notice Video Quality CautionFrame Rate Notice Regarding User-Selected Options Description Getting StartedBUILT-IN Analytics ModelsParts List Camera LayoutProduct Label Remove Back CoverInstallation PinC2953M-A 5/09 Service Cable Attaching the 2.5 mm Monaural Headphone PlugALARM, RELAY, and 24 VAC Connector WiringCAT5 Cable Connecting a Relay Device Connecting AlarmsAlarm Connections Accessing the IP Camera Using a WEB BrowserOperation Live Video Live Video page IconsSelect a Stream Take a SnapshotMaximize the Viewing Area Open the Stream in a NEW WindowChanging the Screen Layout Multiscreen ViewSettings Settings Page MenusSystem TAB General SettingsChanging the Device Name Time Settings Reboot CameraRestore ALL Camera Defaults Configuring the Camera Date and Time SettingsNetwork TAB GeneralChanging the Hostname Dhcp OnSSL Dhcp OffGenerate Certificate Request Generate Self-Signed CertificateSSH Imaging TAB OrientationDigital Processing Exposure Auto ExposureAuto Exposure Manual Exposure Manual ExposureAuto Day Night DAY NightManual Day Night Focus Auto FocusManual Focus Tone MAP White Balance Auto White BalanceManual White Balance Select Preset Video Streams TABCustom Configuration Resolution Compression StandardsImage Rate Bit RateProfile Rate ControlGOP Structure Users Users and Groups TABCreating a New User Editing a User Deleting a User Groups Creating a New GroupEditing a Group Deleting a GroupGeneral Settings Creating an Alarm Event Source Events TABSources Creating a System Event SourceEditing an Event Source Creating a Timer Event SourceDeleting an Event Source Handlers Creating a Send Email Event HandlerCreating a Write Jpeg to SD Card Event Handler Creating an Upload Jpeg to FTP Server Event HandlerExample Handler Filter Setup Creating an Open/Close Relay Event HandlerEditing an Event Handler Deleting an Event HandlersHelp Menu Log Off MenuSpecifications GeneralElectrical MechanicalEnvironmental Analytics RequirementsPhysical C2953M-A 5/09 Page Product Warranty and Return Information
Related manuals