Figure 5. Ferrite Installation
WARNING: The ferrite must be installed for the camera to meet FCC Class B compliance standards. Failure to correctly install the ferrite might cause harmful interference to radio communications.
6.Connect the necessary wiring for alarms and relays (refer to Wiring on page 14).
7.Apply power to the camera. The camera will complete a configuration sequence; the green LED flashes five times per second for approximately two minutes, and then turns solid after the sequence is complete.
NOTE: If the camera is not connected to a DHCP server and DHCP is enabled, the configuration sequence might take up to five minutes to complete.
8.View the camera image using the service jack or a Web browser (refer to Accessing the IP Camera on page 17).
9.Focus the lens:
a.Press the auto back focus button, located on the side of the camera, once to center the focus mechanism.
b.Manually adjust the zoom and focus of the lens to the desired field of view (refer to the instructions shipped with the lens).
c.Press and hold the back focus button for three seconds to start the auto back focus mechanism.
12 |
|