24 VAC CONNECTIONS (OPTIONAL)

If PoE is not used, the camera includes a 24 VAC power connector. Connect the power cable to the 2-pin power connector on the back of the camera using the terminal block connector (provided). Refer to Recommended Wire Gauge and Wiring Distances on page 18.

The power supply connector is shown in Figure 6. Use only a Class 2 isolated power supply. Refer to Specifications on page 25 for power consumption.

The following are the recommended maximum distances for 24 VAC applications and are calculated with a 10 percent voltage drop. (Ten percent is generally the maximum allowable voltage drop for AC-powered devices.)

Table B. Recommended Wire Gauge and Wiring Distances

 

 

Wire Gauge

 

Voltage

 

 

 

 

18

16

14

12

 

(1.0 mm2)

(1.5 mm2)

(2.5 mm2)

(3.5 mm2)

24 VAC

215 ft

341 ft

542 ft

863 ft

 

(97 m)

(154 m)

(245 m)

(391 m)

 

 

 

 

 

NOTE: Power consumption is 18 VA per unit. Use a power source with a minimum of 18 VA per unit.

CONNECTING A RELAY DEVICE

The Spectra Mini IP dome system has an output for triggering an external device. It supports both momentary and continuous relay operation.

You can operate the relay interactively, during an active connection, or automatically to coincide with certain events. Typical applications include activating a door, gate or lock, or switching on lights or other electrical devices.

WARNINGS:

Do not exceed the maximum rating of 12 VDC, 0.15 A.

The green/white wire is internally connected to the dome chassis. Any connected signaling device should be left floating with respect to the dome chassis, otherwise damage may result.

Figure 11 on page 18 shows how to wire the relay with its power source to the Spectra Mini IP.

DC

_ +

Figure 11. Relay Wiring Example

Aux -

Aux +

18

C3446M (7/08)

Image 18
Contents Spectra Mini IP Dome System Contents List of Illustrations Important Safety Instructions Regulatory Notices Radio and Television InterferenceDescription System ModelsDescription Parts List Qty DescriptionBasic System Configurations Dhcp Network Endura NetworkPrivate Network Private Network ExampleStatic Network Static Network ExampleCover and Back Box Installation Surface Mount InstallationCeiling Installation Recessed Installation Suspended Ceiling Removing the Surface Mount Ring Hard Ceiling Wiring Tables CAT5 CablePosition Terminal Block Connecting a Relay Device Wire GaugeVAC Connections Optional Connecting Alarms Supervised AlarmsUnsupervised Alarms Show the wiring configuration for unsupervised alarm inputsAlarm Connections Alarm Return Alarm Alarm Alarm +Reset Button Mode Function Unit Status Indicator LightTroubleshooting Problem Possible Cause Suggested RemedyNo dome system power Specifications MechanicalLens Product Warranty and Return Information ISO9001