Pelco BB5L operation manual Back BOX Connections, Dome 1 Power Dome 2 Power Dome 3 Power

Page 13

WARNING: Make sure you wire power to the outer connectors of the terminal block and ground to the middle connector. Otherwise, you could damage the dome.

3.4 BACK BOX CONNECTIONS

Depending on the type of dome, refer to either Figure 10 or 11 to attach the wiring to the interconnect circuit board inside the back box. Also refer to Figure 6 or 7 if necessary.

1.Earth Ground - Connect earth ground to the middle connector on the power connector.

2.Power - Connect 24 VAC from the transformer to the outer terminals on the power connector. It does not matter which lead goes to which terminal.

If you are wiring more than one dome from the same transformer, it is impor- tant to wire the power connector in each dome the same way. That is, the wiring from one side of the transformer must be connected to the same con- nector on each dome. If you reverse the wiring, the cameras will be out of phase with each other and may produce what appears to be vertical roll when switching between cameras. Refer to Figure 9 for a wiring diagram.

3.Video - Connect the coaxial cable to the BNC video connector.

EXAMPLE: If each dome requires 20 vA, three domes require a 60 vA transformer.

Figure 9. Transformer Wiring

DOME 1 POWER

DOME 2 POWER

DOME 3 POWER

HTR/FAN

RS-422

CONTROL

SIGNALS

1

VIDEO

CONNECTOR FOR OPTIONAL TRANSLATOR SUBASSEMBLY

2RX–

3ALARMS RX+45TX–

 

6

TX+

 

7

 

 

GND

 

 

NO

RELAY

AUX 1

COM

 

NC

 

 

 

 

AUX 2

 

 

GND

 

 

 

FUSE

 

IN

24 VAC

 

PWR

 

MIDDLE

 

 

PIN IS

 

 

GND

POWER

 

 

(24 VAC ONLY)

 

1.6 A

DOME DRIVE CONNECTOR

FAN

Figure 10. Interconnect Circuit Board Electrical Connections for Spectra™ (Ver. 3.0) and Spectra II™

Pelco Manual C1488M-A (9/98)

13

Image 13
Contents Listed Contents General Important Safeguards and WarningsRegulatory Notices Recommended Tools Unpacking InstructionsIN-CEILING Models Pendant ModelsModels DescriptionCertifications FCCProceed to .2, Wiring Installation for IN-CEILING ModelsCeiling and Back BOX Preparation Proceed to .3, Back BOX Installation WiringMaximum Distance RG6/UHard Ceiling Ceiling Tile Wiring Diagram for Spectra Ver .0 and Spectra Wire Gauge Proceed to .4, Back BOX Connections Back BOX InstallationBack BOX Connections Dome 1 Power Dome 2 Power Dome 3 PowerRX+ TX+ From controller To 4-Wire terminal on circuit boardPENDANT-MOUNT Installation Installation for Pendant ModelsSURFACE-MOUNT Installation Symptom LED does not light TroubleshootingMechanical SpecificationsElectrical GeneralSD5 Series Dimension Drawing Pelco Manual C1488M-A 9/98 Warranty Warranty and Return InformationReturns