| CONNECTOR | |
HTR/FAN | VIDEO | FOR OPTIONAL | |
TRANSLATOR | |||
|
SUBASSEMBLY | ||
CONTROL | ||
| ||
SIGNALS |
|
PWR IN
RX–
RX+
TX–
TX+
FUSE
24 VAC
MIDDLE
PIN IS
GND
DOME DRIVE CONNECTOR
FAN
NOTE: Connect only a low volt- age device to the relay output. Maximum current rating of the re- lay contacts is two amperes.
CAUTION: The maxi- mum output of AUX 2 is 150 mA. If you connect a device that draws more current, you could destroy the output transistor. The output is intended to drive logic circuits or
CAUTION: Leave ad- equate slack in the wiring to permit the door to open without pulling on the con- nectors.
POWER |
|
(24 VAC ONLY) | 1.6 A |
Figure 11. Interconnect Circuit Board for Spectra™ Lite
4.Control - If you are using a Coaxitron® controller, control signals will be trans- mitted over the video coax.
If you are using
From controller | To |
RX- | TX- |
RX+ | TX+ |
TX- | RX- |
TX+ | RX+ |
|
|
5.Heater/Fan - The heater/fan is not used on indoor models.
6. | Alarm Inputs - (Spectra™ [Version 3.0] and Spectra II™ Only) If you need |
| alarm inputs, connect them. The maximum number of alarm inputs is seven. |
| Refer to Figure 6 for a typical wiring example. Alarm inputs require a ground |
| signal through a contact closure, such as a switch. |
7. | AUX 1 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 1 com- |
| mand from the controller will activate the relay output. If you need the relay, wire |
| it as required. Refer to Figure 6. The relay contacts are shown when AUX 1 is |
| inactive. When an AUX 1 command is issued, the relay contacts will reverse and |
| remain latched until a clear command is issued. |
8. | AUX 2 - (Spectra™ [Version 3.0] and Spectra II™ Only) An AUX 2 command |
| from the controller will place a ground at the output of AUX 2 to operate the device |
| connected to it. The output will remain latched until a clear command is issued. If |
you need the AUX 2 output, wire it as required. Refer to Figure 6 for typical wiring examples.The AUX 2 output is an open collector transistor driver which is capable of passing a maximum of 150 mA at 32 VDC. It is capable of driving TTL logic circuits or
9.Close the door and tighten the thumbscrew securely.
10.Turn on power to the back box. The red LED on the interconnect door should light. The fan will not operate until a dome drive is installed.
If the LED does not light, correct the trouble before proceeding. Refer to Sec- tion 5.0, TROUBLESHOOTING.
14 | Pelco Manual |