Pelco 13M15-50, 13M2.8-8, 13M2.8-12 important safety instructions Routine Servicing, Specifications

Page 3

Routine Servicing

A special coating has been applied to the lens surface to prevent light reflection. A dirty lens surface due to dust, oil, or fingerprints causes harmful glare, which degrades the lens properties. Dirt can also cause mold or scratches on the lens.

NOTE: Be careful not to damage the lens while cleaning.

To remove dust, brush or dust off the lens with an oil-free soft brush or blower brush (for photography use).

To remove oil, fingerprints, or water drops:

1.Apply alcohol or lens cleaning liquid to a clean, soft, oil-free cotton cloth or lens cleaning paper. Using a spiral motion, moving from the center of the lens to the rim, gently wipe the lens.

2.With another clean soft cloth, gently wipe off the rest of the dirt, and then dry the lens surface.

3.Repeat this process as necessary until the lens is completely clean.

Specifications

 

13M2.2-6

13M2.8-8

13M2.8-12

13M15-50

Type

Varifocal

Varifocal

Varifocal

Varifocal

Format Size

1/3-inch

1/3-inch

1/3-inch

1/3-inch

Mount

CS mount

CS mount

CS mount

CS mount

Focal Length

2.2~6.0 mm

2.8~8.0 mm

2.8~12.0 mm

15.0~50.0 mm

Zoom Ratio

2.7X

2.8X

4.3X

3.3X

F-number (iris fully opened)

1.3~2.0

1.2~1.9

1.4~2.7

1.5~2.2

Image Size

6 mm diameter

6 mm diameter

6 mm diameter

6 mm diameter

Flange Focal Length

12.5 mm

12.5 mm

12.5 mm

12.5 mm

Minimum Object Distance

0.3 m

0.3 m

0.3 m

0.8 m

Iris

Auto

Auto

Auto

Auto

Field of View

 

 

 

 

Wide

 

 

 

 

Vertical

92°

74°

74°

14°

Horizontal

120°

100°

100°

18°

Diagonal

146°

128°

127°

23°

Tele

 

 

 

 

Vertical

35°

26°

18°

4.2°

Horizontal

47°

35°

23°

5.6°

Diagonal

58°

44°

29°

6.9°

Focus

Manual

Manual

Manual

Manual

Zoom

Manual

Manual

Manual

Manual

Operating Temperature

14° to 122°F

14° to 122°F

14° to 122°F

14° to 122°F

 

(-10° to 50°C)

(-10° to 50°C)

(-10° to 50°C)

(-10° to 50°C)

Storage Temperature

-4° to 140°F

-4° to 140°F

-4° to 140°F

-4° to 140°F

 

(-20° to 60°C)

(-20° to 60°C)

(-20° to 60°C)

(-20° to 60°C)

Relative Humidity

35% to 90%

35% to 90%

35% to 90%

35% to 90%

Iris Drive Coil Resistance

190 Ω ±10%

190 Ω ±10%

190 Ω ±10%

190 Ω ±10%

Iris Damping Coil Resistance

500 Ω ±10%

500 Ω ±10%

500 Ω ±10%

500 Ω ±10%

Maximum Iris Operating Current

23 mA at 4 VDC

23 mA at 4 VDC

23 mA at 4 VDC

23 mA at 4 VDC

Height

1.79 in. (4.55 cm)

1.79 in. (4.55 cm)

1.97 in. (5.00 cm)

1.79 in. (4.55 cm)

Diameter

1.48 in. (3.75 cm)

1.48 in. (3.75 cm)

1.80 in. (4.57 cm)

1.48 in. (3.75 cm)

Length

2.13 in. (5.40 cm)

2.05 in. (5.20 cm)

2.58 in. (6.55 cm)

2.30 in. (5.85 cm)

Unit Weight (approximate)

0.12 lb (0.05 kg)

0.11 lb (0.05 kg)

0.13 lb (0.06 kg)

0.13 lb (0.06 kg)

NOTE: When power is turned off, the iris will close automatically.