JAI CV-M531, CV-M530 operation manual EIA Non-interlaced / Field accumulation mode

Page 9

 

CV-M530/531

 

To use this mode

Set:

SW1-4 to ON for ext. trigger shutter

 

SW1-5 to OFF for field accumulation

 

SW1-6 to ON for non-interlaced

 

SW1-1,2 and 3 to shutter speed

Input:

Ext. trigger to pin 5 on 6 pin multi connector.

 

Ext. HD to pin 6 on 12-pin multi connector. (If used).

 

75 Ohm termination is done with SW2-1 (HD) and SW2-2 (ext.trigger) on PK8057 board.

Refer to Timing Chart and Cautions below.

Detailed switch and jumper setting is described in “7. Mode Setting”.

For connections see “5. Pin Assignment”.

Cautions in the Edge Pre-select Mode.

1.Edge pre-select mode is effective only in non-interlaced, field accumulation mode.

2.The exposure start may delay up to 1H max., when the falling edge of ext. trigger pulse is not synchronized with the falling edge of ext. HD signal. To avoid this 1H delay and jitter, the falling edge of the trigger pulse should be synchronized with the HD pulse as shown below. It can be the ext. HD input or the Internal HD output.

3.The ext. trigger input is 75 Ohm terminated as factory setting. (R127 short and SW2-2 ON). The

voltage level of the ext. trigger has to be 4.0 Vp-p ± 2.0 V. The duration should be more than 1 H negative going. >64 µsec. and < 60 msec. The input is AC coupled.

4.If the ext. trigger input and ext. HD input are from a source with TTL level, set SW2-1 and SW2-2 OFF for non-terminated. SW2-1 for HD signal, SW2-2 for ext. trigger pulse. See “7.2 SW2 on PK8057 Board”.

EIA (Non-interlaced / Field accumulation mode)

Edge pre-select mode (for non-interlace only)

EIA : 1H = 63.5s

 

 

TRIG

 

 

 

1H

TRIG in

 

1H more

 

 

 

 

EXT HD

 

 

 

 

 

 

INT HD

 

 

 

 

 

 

INT VD

 

 

 

 

 

 

1.5H

9H

 

9H

1H

1.5H

9H

EEN

 

 

 

 

 

0.5H

Exposure time

12.5H

 

 

Exposure time

 

0.5H

 

 

 

 

 

 

WEN

10.5H

2H

9H

 

 

 

 

 

 

 

CCD out

 

 

Effective pixels

 

 

 

 

 

 

 

 

 

 

 

 

No.10 to 251

 

 

 

Video out

 

20H

242H

20H

 

 

 

 

 

 

 

 

Blanking

Effective video

Blanking

 

 

 

 

 

- 8 -

 

 

 

Image 9
Contents CV-M530/531 Declaration of Conformity Table of Contents Standard Composition GeneralMain Features Locations and Functions 235Pin Multi-connector DC-IN/SYNC Pin AssignmentType HR10A-7R-6PB Hirose male Seen from rear Normal Shutter Mode Input/Output of HD/VD SignalExternal Trigger Mode Functions and OperationsEdge pre-select mode for non-interlace only EIA Non-interlaced / Field accumulation modePulse Width Control Mode Ccir Non-interlaced / Field accumulation modePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M530/531 EIA Ccir Long Time Exposure ModeCV-M530/531 Mode Setting Table for SW 1 SettingTable for Shutter Time SW2 on PK8057 Board Pixel Clock Output Jumper SettingsLocation of SW2 and Jumpers Board PK8054 Side BBoard PK8057 Side a Adjustment of Video Signal Output Level External Appearance CCUHead Spectral Sensitivity SpecificationsPrecautions Typical CCD CharacteristicsAppendix User’s Record Users Mode SettingsCamera type CV-M530/531 Scanning system Revision Revision E Serial No