JAI CV-A1-20 operation manual Smearless Mode

Page 17

CV-A1-20

6.10. Smearless Mode

This mode will reduce the unwanted smear signal from a highlighted scene when a short exposure time is used. The trigger mode is like edge pre-select, but a dummy readout is performed before the active accumulation is started. It will remove the smear above the highlighted parts in the image, but there is still smear left below highlighted areas.

The trigger leading edge will start the dummy readout. It takes 54 H before the exposure starts. The exposure stops and the resulting video signal is read out after the selected shutter time. It can be the 16 step normal or 1023 step programmable. SM=0 or SM=1.

This mode will operate with full and partial scanning and with all binning modes. Partial scanning together with binning will work, but it is not described, and no timing diagrams will be documented. An EEN pulse will indicate the active accumulation time, and a WEN pulse indicates that the resulting video is being read out.

To use this mode:

 

Set function: Trigger mode “Smearless read out”

TR = 6

 

Shutter mode “Normal” or “Programmable”

SM=0, SM=1

 

“Shutter Speed”

SH=0 through 9

 

“Programmable exposure”

PE=1 through 1023

 

Polarity and other functions

 

Input:

Ext. trigger to pin 5 on 6 pin connector (or pin 11 on 12-pin connector).

 

Ext. HD to pin 6 on12-pin connector. (If used).

 

Important notes on using this mode.

The start of exposure will start synchronized to the internal H signal. The start may be shifted max 1H. To avoid this shift (1 H jitter), synchronize the camera to an external HD and make sure that the trigger pulse aligns to the HD as shown in fig. 17.

The duration of the trigger should be >1H to <2000H.

A new trigger must not be applied before WEN is high.

In trigger modes there are no continuous VD out, only after each trigger input.

1H = 83 6 s

No equalize and serration pulses.

 

A

B

C

D

E

 

Max frame rate

Remarks

Scan mode

 

 

CCD array line #

Effective video

 

 

fps

 

Full

10H

14H

4 to 1038

1035H

18H

 

11

 

1/2 Partial

17H

33H

271 to 783

513H

25H

18

 

1/3 Partial

17H

33H

357 to 697

341H

25H

25

 

1/6 Partial

17H

33H

442 to 612

171H

25H

38

 

H binning

10H

14H

4 to 1038

1035H

18H

11

 

V binning

10H

14H

18 to 1019

501H

18H

20

 

V+H binning

10H

14H

18 to 1019

501H

18H

20

 

Fig. 25. Smearless Mode

- 16 -

Image 17
Contents CV-A1-20 CV-A1-20 Table of ContentsGeneral Standard Composition Main FeaturesLocations and Functions Pin Assignment Pin Multi-connector DC-IN/VIDEO OUT, EXT.HD/VDPin Multi-connector Trigger Video output Input and Output CircuitsTrigger input HD and VD inputBasic functions CV-A1 Block DiagramFunctions and Operations PWC H synchronous accumulation PWC asynchronous accumulation Ext. HD and ext. VD phase conditions Input-output of HD/VD SignalsContinuous Operation Non triggered Edge Pre-select Mode.TR=1 External Trigger ModesTable showing the figures for the different modes Edge Pre-select ModePulse Width Control trigger mode Pulse Width Control ModeFrame Delay read out mode Frame-delay read out ModeLong time exposure Long Time Exposure ModeStart/Stop mode Start/Stop ModeSmearless Mode Smearless ModeRS-232C control Configuring the CameraOther Functions Timing and shutter related commands CV-A1-20 RS-232C command listCamera Control Tool for CV-A1-20 Internal Switch and Jumper Settings External Appearance and DimensionsSpectral Sensitivity SpecificationsAppendix PrecautionsTypical CCD Characteristics Declaration of Conformity Users Record