Hitachi BE-IR20 manual BE-IR21 internal sync

Page 17

11. Function setting and changes

11-6 BE-IR21 internal sync

The BE-IR21 factory setting is for external sync. If required, this can be changed to internal sync by changing chip parts.

Change the following chip parts for internal sync operation.

 

Sync system

 

R280

 

R281

 

R282

R284

 

 

External

 

Absent

 

0

 

100

Absent

Factory setting

 

Internal

 

100

 

Delete

 

Delete

0

 

 

0

Part code

RME1784

 

 

 

 

 

Type

 

ERJ3GEYJ0R00V

 

100

Part code

RME1797

 

 

 

 

 

Type

 

ERJ3GEYJ101V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Main board side A)

(Main board side B)

Location of chip resistors

BE-IR20 / 21

16

Image 17
Contents Infrared B/W Camera Module Operation Guide Table of Contents Introduction SpecificationsGeneral Composition.Specifications BE-IR20 BE-IR20 External view Optical dimensionsTwo 2.5 mm Dia InstallationBLK GRN YEL RED Typical connectionGND Typical connectionExternal sync BE-IR21 AGC on / off Function setting and changesGamma response Function setting and changesAuto electronic shutter on / off Fixed Changes to fixed shutter modeBE-IR20 external sync BE-IR21 internal sync HD and VD output BE-IR20 only Options Options BE-IR20/21 and LA-IR20 combined dimensionsSpectral sensitivity typical example U t i o n