Hitachi BE-IR20, 21 manual Function setting and changes, Gamma response

Page 13

11. Function setting and changes

11-2 Gamma response

The factory setting is gamma on. If necessary , the gamma response can be changed as follows.

Change the gamma response by changing the chip part.

 

Gamma(γ )response

R217

R218

R219

 

 

 

ON

Absent

0Ω

0Ω

Factory setting

 

OFF

0Ω

Remove

Remove

 

 

0Ω : Part code

RME1784

 

 

 

 

Description

ERJ3GEYJ0R00V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location of chip capacitors (Main board side B)

BE-IR20 / 21

12

Image 13
Contents Infrared B/W Camera Module Operation Guide Table of Contents Introduction SpecificationsGeneral Composition.Specifications BE-IR20 BE-IR20 External view Optical dimensionsTwo 2.5 mm Dia InstallationBLK GRN YEL RED Typical connectionGND Typical connectionExternal sync BE-IR21 AGC on / off Function setting and changesGamma response Function setting and changesAuto electronic shutter on / off Fixed Changes to fixed shutter modeBE-IR20 external sync BE-IR21 internal sync HD and VD output BE-IR20 only Options Options BE-IR20/21 and LA-IR20 combined dimensionsSpectral sensitivity typical example U t i o n