4)CCD MODE:CCD store mode changeover

FLD: The field store mode operation is performed (for ordinary purpose of application).

FRM:Frame store mode operation is performed. The vertical resolution can be increased but the degree of after-image becomes slightly higher. It is therefore recommended to use the FRM function when taking a still image.

(Note) When the shutter mode is AES, even if set to frame, the camera operates in the field mode. In the Auto CAM mode, The CCD mode is set to FLD.

5)DTL FREQ:DTL amplifying frequency changeover.

L R

 

LOW

 

STANDARD

 

HIGH

 

 

 

 

 

 

 

 

LOW:The lower band frequency is amplified.

STANDARD:The standard amplification is performed.

HIGH:The high band frequency is amplified. Finer contour correction is carried out.

6)GAIN HIGH:Gain setting in GAIN HIGH mode (At the time of AGC:OFF mode)

L R

BD1+ BD01+

The gain level can be set in a range of +1 to +10 dB.

Cannot be set in the Auto CAM MODE.

7)GAIN MAX:Gain setting in GAIN MAX mode (At the time of AGC:OFF mode) The gain level can be set in a range of +11 to +20 dB.

Cannot be set in the Auto CAM MODE.

8)AGC:Upper gain limit setting in AGC mode (At the time of AGC:ON mode)

The upper limit of gain increase in AGC operation can be set in a range of +6 to +20 dB.

9)MESSAGE RTN:Message display ON/OFF

ON :A message indicating the result of AWB/ABB execution in the DIRECT mode is displayed.

OFF:A message indicating the result of AWB/ABB execution in the DIRECT mode is not displayed.

19

Image 32
Contents Model HV-D25 Cleaning AccessoriesPower Sources Read InstructionsPower-Cord Protection Damage Requiring ServiceReplacement Parts Safety CheckAmplifiers that produce heat Alle Anweisungen lesen Die Anweisungen aufbewahrenWarnungen beachten Anweisungen befolgenStromversorgung Erdung oder PolarisierungNetzkabelschutz BlitzschlagBeschädigung, die Wartung erfordert ErsatzteileSicherheitsprüfung Anbringung an der Wand oder an der DeckeAccessoires Lire les instructionsConserver ces instructions Tenir compte des avertissementsMise á la terre ou polarisation Protection du cordon d’alimentationFoudre Surcharge21. Piéces de rechange 22. Vérificaton de sécuritéMontage au mur ou au plafond ChaleurImportant Notice Table of contents Page Standard composition Important safety notes Operating considerationsCCD properties Continuous operationTransportation Moire Rear panel facilities Lens Lens selectionFixed focus lens Zoom lensLens Camera mounting System examples SYN Multi-camera computer control Page Menu Screen Operation Menu Structure Main Menu StructureSpecial Menu Structure PRST320K Main MenuAuto FO MODE1 2EDOM Lamron HGI MAX AGCUltra Gainultra Gain ON/OFF BLACKMaster black level setting SUB MenuBD1+ BD01+ HighKneeknee ON/OFF Auto Kneeauto Knee ON/OFFALC WindowSpecial SET Spb0526 Spb084 960bps 1920bpsLens Page Level Iris GateWhite Gate Menu for setting the masking MaskingWhite BAL InitializeGL Mode 12OUTPUT/SYNC13 ID/TITLE ‹0 90‹ 180‹ 270‹DTL Gamma Application Files APP-1,APP-2,APP-3 Common file settings ID/TITLEBlack Balance Adjustment White Balance Adjustment Long Shutter Mode Change Shutter Mode TRY Again CAM ModeautoChange to MEM 5600K Change to MEM 3200KRealtime Auto White Auto Shading CorrectionALC Lock scan mode shutter speed setting Long-Time Store Mode Ab+ Ac+Connection to RC-C10 remote control box Menu mode Lock switch∙ 0 dB Normal mode Option 1 button ABB/R auto black balance/right buttonRemote status LED Remote switch ∙ Auto Over-ride adjustable about 2 f-stops ∙ RemoteAuto Over-ride adjustable about 2 f-stops Remote LED indicatorsAPP-1 APP-3 APP-2 MenuscreenOperation Menu screen customizingMain menu screen Special menu screen Items stored in applications files Application files APP-1, APP-2 and APP-35000 K Items stored in common file Function Selection by Internal Switch Setting ConnectorsEXT B-Y SpecificationsNTSC,PAL AES Ntsc SmpteInput/Output Signals Major accessories Dimensions