Empire Products K550 operation manual Remove the lead connector E,D

Page 51

Option unit connection

Camera disassembly

1)Remove top cover.

Take out 5 screws and remove the top cover [A].

2)Remove the PROC/MEN unit [B].

Take out 2 screws and disconnect 3 flat cables.

Raise the board towards the lens

side and slide it forward to remove the board.

 

3) Remove the REG/SG unit [C].

 

Take out 2 screws and disconnect 1 flat cable.

Remove the lead connector [E],[D].

Raise the board towards the lens side and slide it forward to remove the board.

Notes:

1.Release the connector lock mechanism when disconnecting the flat cables.

2.Do not open the connector lock lever more than 90 degrees(lever can be damaged).

2 wire unit and adaptor board assembly

Assemble the 2 wire unit and adaptor board, then install in the camera.

1)Overlap the 2 wire unit [F] and adaptor board [G], then secure with 2 screws and threaded plate [H].

2)Engage lead connector [I] with the 2 wire unit [F].

39

Image 51
Contents Sicolor DIG Important Safety Instructions Risk of Electric Shock Do not Open AvertissementVorsicht Important Safety Instructions Page Page Wichtige Sicherheitsanweisungen Page Wenn das Netzkabel oder der Stecker beschadigt ist Mises EN Garde Importantes Page Page Page Page Page Section names and functions Page Page Store the C mount adaptor for possible future use Video Page Page Page Proceed to the next item Page Lens AES AES&LENS Page Page Right button Ascending sequence Left button Page AGC ON/OFF Page Page Page Page Page OFF ManualAuto Night observation ELE-ZOOM Page Sky conditions Illumination OFF/ON Text DISPLAYON/OFFAGCON/OFF White Balance MODEATW/AWC/MANUALWhite Balance Modeatw SC-PHASE COARSE3Light Control Modelens Contrast OFF Area Select NO.NO.1PAL Page Supplied accessories Video output switch setting for 2 wire output Remote interface selection Refer to the next Page External sync operation only with VBS/GL Remove the lead connector E,D Wire unit installation Install the 2 wire unit