RayTek ThermoView Ti30 Centigrade/Fahrenheit Toggle Button, LCD Backlight Illumination Switch

Page 22

Centigrade/Fahrenheit Toggle Button

Centigrade/Fahrenheit button toggles the displayed temperature data in either

Centigrade or Fahrenheit temperature scales. The factory default is Centigrade.

LCD Backlight Illumination Switch

LCD Backlight Illumination switch provides three backlight illumination levels as shown below.

Off

Medium

Full

Full brightness is recommended for indoor use; use Medium brightness to save battery life, and set backlight Off for outdoor applications. The default position is Full brightness.

Palette Switch

The Palette switch allows the ThermoView imager to display temperature patterns in three different palettes as indicated below:

ξ Rainbow

ξ Ironbow

ξ Grayscale

See Selecting the Color Palette on page 42 for more information. The default position is

Rainbow.

Measurement Mode Switch

The Measurement mode switch permits the user to change the way thermal information is presented on the display. Depending on the mode you choose, you will have all temperature points shown on the thermal image, or you may have just a narrow interval of temperature points being displayed at a time. The decision of which mode to use depends on each operator’s needs and limitations.

July 1, 2003

- 22 -

Version 1.0

i

Tel: (01943) 602001- WWW.ISSLTD.CO.UK - Fax: (01943) 816796

i

Image 22
Contents ThermoView Ti30 User’s ManualContents Qualitative and Quantitative Temperature Measurements Appendix B Infrared Theory Q&A Glossary Warranty Information Customer Service Contact Information Introduction Quick Specifications Table NetdUnpacking Your New Imager Removing the Battery Pack First, the BatteriesBattery Packs Charging the Rechargeable Battery Pack Normal Charge CycleDocking Station LED Indicators Getting Started Attaching the Wrist StrapTurning the Unit On Displaying ImagesInformation Screen Normal Mode Settings and Controls KeypadThermoView Imager Settings Switches icons not shown ThermoView Imager Settings Switches Laser On/Off Toggle ButtonJapanese Laser Aperture and Optical ChannelMeasurement Mode Switch LCD Backlight Illumination SwitchPalette Switch Centigrade/Fahrenheit Toggle ButtonAutomatic Semi Automatic Gain and Level ThumbwheelsFocus Wheel Level pointTrigger Location of the Focus WheelMan Machine Interface Flow Charts Main LoopImage Recording Procedure Emissivity Adjustment Procedure July 1 Version Quick Image Fix Procedure Array Recalibration Procedure Recording an ImageRetrieve Mode Retrieving an ImageInstalling the Software Downloading and Looking at ImagesConnecting the Docking Station to Your Computer Hooking Up the Docking StationConnecting the USB Connector to the USB Port InsideIR Main Screen at Program Launch Downloading Images Sync buttonSaving Images Download Data ScreenSetting the Imager Clock Contents of Images FolderJuly 1 Version Field USB Port Looking at Your Downloaded ImagesViewing Thumbnail Images Viewing a Single Image Importance of Focusing Obtaining the Best ImageSelecting the Measurement Mode Selecting the Color PaletteLevelGain Min Level  Gain Max Level  Gain Tip Qualitative and Quantitative Temperature Measurements Distance to Target Spot RatioField-of-View Optical DiagramDS ratio D / S = Ambient Temperatures Environmental ConditionsReflected Temperature Compensation EmissivityReflected Temperature Compensation Organizing Your Data File ManagementUploading Data to the Imager Uploading Data to Your ThermoView Ti30 ImagerEditing Data Before Upload RTC OFF Single Image Screen Analyzing Your DataScale Limits Sample Image at Original Scale Limits Sample Image at Original Isotherm Setting IsothermsTemperature Table Tab Additional Image Analysis ToolsTemperature Table Profile TabHistogram Tab Profile TabMenu Bar New FolderFahrenheit ThermoView Imager InfoExit CelsiusCreate Report Export Temperature TableExport Image HistogramCascade Copy Profile ChartContents Tile HorizontalReporting Your Findings Thermographic ReportImager Accuracy Chart Appendix a Technical ReferenceImager Reading Error vs Source DS Typical Emissivity ValuesAluminum Unoxidized Ni-Cu Gob Appendix B Infrared Theory Q&A Why use noncontact infrared thermometers?How does IR work? How to assure accurate temperature measurement? EmissivityDistance to spot ratio Field-of-viewHow to take temperature measurement? What are the most popular applications?Glossary Calibration Background TemperatureBlackbody Calibration SourceEMI/RFI Noise Display ResolutionDrift Far FieldFull Scale Accuracy Focus Point or DistanceFull Scale Gray BodyMicron or µm LaserLoop Minimum spot sizeOptical Pyrometer Optical ResolutionNon-Gray Body Pyroelectric DetectorRelative Humidity Reflected Temperature CompensationResolution RepeatabilityTemperature Coefficient or Ambient Derating Storage Temperature RangeTemperature Spectral ResponseTime Constant Temperature ResolutionThermal Shock Transfer Standard