Spectral Response

The wavelength region in which the IR Thermometer is sensitive.

Spot

The diameter of the area on the target where the temperature determination is made. The spot is defined by the circular aperture at the target that allows typically 90% of the IR energy to be collected by the instrument, as compared with the 100% spot diameter which is defined by the IR energy collected from a very large target. The actual size and distance to the target for the 100% spot diameter is specified in the calibration procedure for each instrument.

Stare

A saturation effect caused by aiming a sensor at a hot target for an extended period of time and then quickly aiming at a target at a lower temperature. The increase in time (beyond the normal system response) for the sensor to return to within 5 % of the lower temperature is defined as the stare time.

Storage Temperature Range

Ambient temperature range that the thermometer can safely withstand in a non-operating mode, and subsequently, operate with-in published performance specifications.

Target

The object upon which the temperature determination is being made.

Temperature

A degree of hotness or coldness of an object measurable by a specific scale; where heat is defined as thermal energy in transit, and flows from objects of higher temperature to objects of lower temperature.

Temperature Coefficient (or Ambient Derating)

An indication of the instruments ability to maintain accuracy when the ambient conditions are subject to a slow change or drift. The temperature coefficient is usually expressed as the percent change in accuracy per degree change in ambient temperature. For a rapid change in ambient conditions refer to Thermal Shock.

July 1, 2003

- 82 -

Version 1.0

i

Tel: (01943) 602001- WWW.ISSLTD.CO.UK - Fax: (01943) 816796

i

Image 82
Contents ThermoView Ti30 User’s ManualContents Qualitative and Quantitative Temperature Measurements Appendix B Infrared Theory Q&A Glossary Warranty Information Customer Service Contact Information Introduction Quick Specifications Table NetdUnpacking Your New Imager Removing the Battery Pack First, the BatteriesBattery Packs Charging the Rechargeable Battery Pack Normal Charge CycleDocking Station LED Indicators Getting Started Attaching the Wrist StrapTurning the Unit On Displaying ImagesInformation Screen Normal Mode Settings and Controls KeypadThermoView Imager Settings Switches icons not shown ThermoView Imager Settings Switches Laser On/Off Toggle ButtonJapanese Laser Aperture and Optical ChannelMeasurement Mode Switch LCD Backlight Illumination SwitchPalette Switch Centigrade/Fahrenheit Toggle ButtonAutomatic Semi Automatic Gain and Level ThumbwheelsFocus Wheel Level pointTrigger Location of the Focus WheelMan Machine Interface Flow Charts Main LoopImage Recording Procedure Emissivity Adjustment Procedure July 1 Version Quick Image Fix Procedure Array Recalibration Procedure Recording an ImageRetrieve Mode Retrieving an ImageInstalling the Software Downloading and Looking at ImagesConnecting the Docking Station to Your Computer Hooking Up the Docking StationConnecting the USB Connector to the USB Port InsideIR Main Screen at Program Launch Downloading Images Sync buttonSaving Images Download Data ScreenSetting the Imager Clock Contents of Images FolderJuly 1 Version Field USB Port Looking at Your Downloaded ImagesViewing Thumbnail Images Viewing a Single Image Importance of Focusing Obtaining the Best ImageSelecting the Measurement Mode Selecting the Color PaletteLevelGain Min Level  Gain Max Level  Gain Tip Qualitative and Quantitative Temperature Measurements Distance to Target Spot RatioField-of-View Optical DiagramDS ratio D / S = Ambient Temperatures Environmental ConditionsReflected Temperature Compensation EmissivityReflected Temperature Compensation Organizing Your Data File ManagementUploading Data to the Imager Uploading Data to Your ThermoView Ti30 ImagerEditing Data Before Upload RTC OFF Single Image Screen Analyzing Your DataScale Limits Sample Image at Original Scale Limits Sample Image at Original Isotherm Setting IsothermsTemperature Table Tab Additional Image Analysis ToolsTemperature Table Profile TabHistogram Tab Profile TabMenu Bar New FolderFahrenheit ThermoView Imager InfoExit CelsiusCreate Report Export Temperature TableExport Image HistogramCascade Copy Profile ChartContents Tile HorizontalReporting Your Findings Thermographic ReportImager Accuracy Chart Appendix a Technical ReferenceImager Reading Error vs Source DS Typical Emissivity ValuesAluminum Unoxidized Ni-Cu Gob Appendix B Infrared Theory Q&A Why use noncontact infrared thermometers?How does IR work? How to assure accurate temperature measurement? EmissivityDistance to spot ratio Field-of-viewHow to take temperature measurement? What are the most popular applications?Glossary Calibration Background TemperatureBlackbody Calibration SourceEMI/RFI Noise Display ResolutionDrift Far FieldFull Scale Accuracy Focus Point or DistanceFull Scale Gray BodyMicron or µm LaserLoop Minimum spot sizeOptical Pyrometer Optical ResolutionNon-Gray Body Pyroelectric DetectorRelative Humidity Reflected Temperature CompensationResolution RepeatabilityTemperature Coefficient or Ambient Derating Storage Temperature RangeTemperature Spectral ResponseTime Constant Temperature ResolutionThermal Shock Transfer Standard