Elinchrom BX100 manual Switch and Fuse Mains Supply, Mains Switch, Troubleshooting, Mains Fuse

Page 8

Switch and Fuse

Mains Supply

With the MAINS SWITCH (3) switched off ("O" position), firmly push in the plug of the original ELINCHROM mains cord into the mains socket (1).

Mains Switch

The switch should light up when the compact is switched on ("I" position). (Switch off before removing the mains cord).

Troubleshooting

If the on/off switch (3) is ON ("I" position) but not illuminated, switch off the unit and check the mains fuse (2).

If failed replace with the correct fuse and switch ON the unit.

This unit is protected by a thermal circuit breaker to avoid overheating.

Should this occur, the unit turns off automatically and cannot be fired.

After a break for cooling, the flash will be ready again for operation.

See page 11: Troubleshooting

This equipment is not user serviceable and contains high voltages which are dangerous. In the event of failure, please return the unit to an authorized Elinchrom service station.

Mains Fuse

Standard type 5 x 20 mm, (use only tempered fuse) 8 AT (code 19022) for Style 100BX and Style 400BX

Note: Before exchanging a blown fuse, switch off the unit and remove mains cable. Depress and turn the fuse holder anti-clockwise 1/8th, turn and remove it. If the new fuse blows immediately upon reconnection, return the unit to an ELINCHROM service centre for a check-up.

(N.B. Please don't forget to check the correct rating of the fuse !).

Fuse for modelling light

Fast type 5 x 20mm, 4 AF

Switch off the unit and replace the blown fuse with a new one of the correct rating.

The fastblow fuse will protect the triac of the modelling lamp circuit, the lamp and therefore the flash tube.

Mains socket

Modelling fuse

1

4

Mains fuse 2 (Only tempered)

3

Mains switch

7

Image 8
Contents Style BX 100/400 Technical data subject to change Table of contentsFCC Class B Compliance Statement IntroductionStyle 100BX 400BX Declaration of conformity Disposal and recyclingCE marking Notational ConventionsSafety notice Power cableFlash Tubes and Modelling lamps TransportBefore you start Operating instructionsControl Panel Overview of controlsSwitch and Fuse Mains Supply Mains SwitchTroubleshooting Mains FuseModelling light for mains voltage 190/260V Modelling LightModelling lamps and fuse for 90/140V Digital power display PhotocellAudible recharge signal Cordless flash controlEL-Skyport Universal Set Sychronisation socketTraining with Elinchrom lighting Beginner’s Guide To Light Flashtube replacementTo replace the flash tube Features Technical dataEntry Level Flash Heads Pro Flash Head Pro Flash Heads Guarantee Elinca sa