Sanyo HIP-215NHE5 Module wiring, Array Wiring, Electrical Protection, Module Terminations

Page 4

Electrical Specifications￿HIP-205BE11, -205BE11-BO2, -200BE11, -200BE11-BO2, -195BE11, -195BE11-BO2, -190BE11, -190BE11-BO2, -186BE11, -186BE11-BO2, -180BE11, -180BE11-BO2 )

Electrical Specification

Model

HIP

HIP

HIP

HIP

 

HIP

HIP

 

- 205BE11,

- 200BE11,

- 195BE11,

- 190BE11,

 

- 186BE11,

- 180BE11,

 

- 205BE11- BO2

- 200BE11- BO2

- 195BE11- BO2

- 190BE11- BO2

- 186BE11- BO2

- 180BE11- BO3

Cell Number in Series [Pieces]

96

96

96

96

 

96

96

Maximum Power (Pmax) [W]

205

200

195

190

 

186

180

Maximum Power Voltage (Vmp) [V]

56.7

55.8

55.3

54.8

 

54.4

54.0

Maximum Power Current (Imp) [A]

3.62

3.59

3.53

3.47

 

3.42

3.33

Open Circuit Voltage (Voc) [V]

68.8

68.7

68.1

67.5

 

67.0

66.4

Short Circuit Current (Isc) [A]

3.84

3.83

3.79

3.75

 

3.71

3.65

Cell Type

 

 

HIT* (hybrid of a- Si and mono c- Si)

 

 

Maximum System Voltage [V]

1000

1000

1000

1000

 

1000

1000

Factory Installed Bypass Diode

Yes

Yes

Yes

Yes

 

Yes

Yes

Weight [kg]

14

14

14

14

 

14

14

*HIT= Hetero junction with Intrinsic Thin-layer Note: The values in the above table are nominal.

Module wiring

>The maximum number of HIP- xxxNHE5, xxxNHE5-BO2 modules that can be wired in series is seventeen (17).

>The maximum number of HIP- ￿￿￿BE11, xxxBE11-BO2 modules that can be wired in series is thirteen (13).

>When your PV system includes other components (batteries, charge controllers, inverters, etc.), be sure to follow the safety recommendations of their manufactures.

>These modules contain factory installed bypass diodes. If these modules are incorrectly connected to each other, the bypass diodes or cable or junction box may be damaged.

Array Wiring

The term “array” is used to describe the assembly of several modules on a support structure with associated wiring.

Use copper wire that is sunlight resistant and is insulated to withstand the maximum possible system open circuit voltage. Check your local codes for requirements.

Electrical Protection

The HIP- xxxNHE5, -xxxNHE5-BO2,

--xxxBE11, -xxxBE11-BO2 Module complies with the requirements of Electrical protection Class II.

If necessary, the module or array can be grounded.

Module Terminations

A junction box as terminal enclosure is equipped for electrical connections on SANYO modules.

The HIP- xxxNHE5, -xxxNHE5-BO2, -xxxBE11, - xxxBE11-BO2 modules are equipped with MC plugs as terminal enclosure.

Use these MC plugs for electrical connections. Please contact your local dealer with questions regarding other electrical connections for modules.

Junction box configuration and description of terminals (for reference)

Modules equipped with one junction box contain terminals for both positive and negative polarity, and bypass diodes.

Two terminals are dedicated to each polarity (with the polarity symbols engraved onto the body of the junction box ) (see Fig3).

Cable

 

Connector

 

(MC Plug)

 

negative ( - )

positive ( + )

Figure3: Configuration of

junction box

4

Printed in Europe 20.10.2006

Image 4
Contents Introduction ArningDisclaimer of Liability General InformationGeneral Safety InstallationWiring SpecificationsCertification Module wiring Array WiringElectrical Protection Module TerminationsMaintenance DiodesDimension For further information, Please contact