Dimensions
(Module type :
with connector and cable)
dimensions in mm
Label
4 7 Junction
Box
Connector (MC Plug)
Mounting Places (4 places)
Front | Side | Backside |
Section | Section |
Note : In case of installation on a rail structure, module must be attached within the depicted shaded range.
Figure2-1 : Dimension
DIODES
Bypass Diodes
When the modules in series strings are shaded partially, it may cause a reversevoltageacrosscellsor modules, because the current from othercellsin the same series is forced to flow through the shaded area, and then undesirable heating may occur. The use of a diode to bypasstheshadedareacan minimize both heating and reduction of array current.
All SANYO modules are equipped with factory installed bypass diodes. The
MAINTENANCE
Some maintenance is recommended to maintain optimal output performance of solar cell modules. If the module surface becomes dirty, it may cause reduction of output power. It is recommended to clean the surface with water and soft cloth or sponge. A mild
If you need electrical and mechanical inspection or maintenance, it is recommended to have the authorized professional carry out the inspection or maintenance to avoid the hazards of electric shock or injury.