5-2 Line-Lock Control

Matching the vertical synchronization with the power frequency is called the Line- Lock.

This function is activated when the LL of Mode Setting Switch is on.

When two or more cameras are switched by the video switcher for viewing by a monitor TV, the vertical sync. phase can be locked with the power frequency, and a stable vertical sync. is obtained without being disturbed at the time of switching.

Video Monitor

VIDEO SWITCHER

CAMERA1

TO AC 24V UL Listed class 2 power supply

• When connecting to DC power supply, the Line-Lock function is not activated.

CAMERA2

Note :

The camera is synchronized to the power frequency of 60± 1Hz covering a normal fluctuation of the power frequency. However, the camera may not cover a large fluctuation caused from the power generated by an engine generator, etc.

It takes about 10 seconds or more until a stable synchronization is obtained after the power is turned on. This is normal, because several seconds are required to stabilize the camera against power noise.

Refer to “7. LINE-LOCK PHASE” for adjustment.

- 6 -

Image 7
Contents IK-VR01A Attachments Important SafeguardsField Installation Components Features & DescriptionPart Names & Functions Mode Setting Switch Lens Iris ADJDo not overload power supply Basic connection single system configurationConnections and Operations Line-Lock Control Video Switcher CAMERA1Adjust the Angle of View InstallationsImportant Notice Tilt rotation Installing the Camera Unit 46 mm Change of Dome Cover Dome replacementLine Lock Phase Condition Check Points Case of ProblemsMinimum Illumination SpecificationsExterior View 150 Mounting Base Bracket