Toshiba IK-HD1E Menus, SHUTTER䋨Electronic shutter䋩, Auto Manual, Flicker may be large

Page 17

7 2 Menus

Select the menu to change the setting by referring to the item “7.1 Using the Menus”.

When the [MENU UP], [MENU DOWN] buttons are pushed, the “ ” on the screen moves up and down. Move the “ ” to the item whose setting you wish to change.

1 SHUTTERElectronic shutter

The electronic shutter has four modes; AUTO, MANUAL, SS(Synchro. Scan).

Press the “Page” button to enter the Shutter Page. Use the “Data Up/Down” buttons to select the Shutter Mode.

 

AUTO

MANUAL

SS

AUTO

The exposure time is controlled automatically to obtain the video level set.

MANUAL

It is possible to select the exposure time from eleven speed settings; OFF (1/60s), 1/100s,

 

1/125s, 1/250s, 1/500s, 1/1000s, 1/3000s, 1/5000s, 1/10000s, 1/30000s, 1/50000s.

 

Note:

 

 

 

When setting a rapid shutter speed, sensitivity degrades according to the speed.

 

When a discharging light such as fluorescent lamp, etc. is used for the illumination,

 

the flicker may be large.

 

 

SS

Shutter speed can be set by the horizontal scanning time (1H) unit.

17

Image 17
Contents IK-HD1E Safety Precautions Disclaimer Limitation of Usage Table of ContentsOption Handling the unit ComponentsItems Controlled by the on Screen Display Available selections Preset value Factory settingNames and Functions Standard Connection ConnectionPB/PR HD-SDIConnection on Back Panel Back panel view 3A Connector Pin AssignmentsGND TXD RXD GNDDisplay Meaning OperationAutomatic Black Balance White Balance Features䋨Automatic Tracking 䋨Manual White Balance䋩AWB OK Gain Scene FileAutomatic shading correction operation finished correctly Shading CorrectionUsing the Menus Mode Setting by the on Screen DisplaySHUTTER䋨Electronic shutter䋩 MenusAuto Manual Flicker may be largeChanging the automatic shutter response speed 䋨1䋮1䋩 Changing the setting in Auto modeChanging the video level in the automatic shutter mode Changing the automatic shutter zone area Preset a Preset B Preset C Preset D Preset E䋨1䋮3䋩 Changing the setting in SS Synchro. Scan mode 䋨1䋮2䋩 Changing the setting in Manual modeChanging the shutter speed setting Changing the shutter speed䋨2䋮2䋩 Changing gain in Manual mode Mode Auto MAX GainGain Video gain ModemanualConfirming the contents of the zone area selected by AWB Changing color temperature setting䋨3䋩 WHT BALWhite Balance Changing R PaintMode ATW Paint Mode Manual Gain Temp 䋨3䋮3䋩 Changing gain in Manual modeChanging the red gain Changing the blue gain䋨4䋮2䋩 Changing gamma correction level 䋨4䋩 Process䋨4䋮1䋩 Changing gamma correction ON/OFF 䋨4䋮5䋩 Changing DNR Digital Noise Reduction 䋨4䋮3䋩 Changing detail outline gain䋨4䋮4䋩 Changing master pedestal 䋨5䋮1䋩 Changing Matrix color correction ON/OFF 䋨5䋮2䋩 Changing Matrix setting䋨5䋩 MATRIXMatrix color correction Adjusting horizontal phase 䋨6䋮2䋩 Changing EXT. setting䋨6䋩 Sync 䋨6䋮1䋩 INT screen䋨7䋮2䋩 Changing shading correction mode 䋨7䋮1䋩 Changing Output mode䋨7䋮3䋩 Changing manual shading correction mode 䋨7䋩 Option䋨7䋮6䋩 Changing OSD Output mode 䋨8䋩 Returning to factory settingsOutput RGB RGB SyncUsing the unit with external sync signal 䋨1䋩 External sync signal input conditionsSetting by 1H External SyncSymptom Items to be checked Before Making Service CallCCD SpecificationsSync EXCExternal Appearance Diagram Limited Warranty Toshiba CCD Camera