14. Special functions Rapid
Fig. 30: Automatic cut-out
The Rapid function
Recycling times in the A and TTL modes depend on the amount of light required for the shot. Recycling takes 11 seconds max. when
Use of the Rapid function is especially valuable when taking shots inside a room, where fast recycling is more important than a maximum light output. However, the guide number is reduced by 1 increment, e.g. from GN 40 (with ISO 100/21° film - 50 mm zoom) to GN 28 (with ISO 100/21° - 50 mm zoom).
☞Partial light output levels are not possible with the Rapid function.
Automatic cut-out
If you set the
The last used operating mode, or the last set user program is retained when the flashgun is switched off so that it becomes instantly available when the flash is
switched on. Press the „+“ or | to switch on again. |
14. Special functions |
Testing the LCD segments and m-ft changeover (Service Menu)
The Service Mode 1 has to be called in order to check the LCD segments and to change over the dimensional units (m = meter; ft = feet).
☞Only complete the settings described here! Do not press any other buttons than those described here, otherwise there is the danger that programmed data and user programs will be lost!
Calling the Service Mode 1:
• Press the button | for the LC display light and simultaneously slide the main | ||
switch | from OFF to ON. If a Pentax adapter is used, hold down button | for | |
at least 2 seconds after sliding the main switch . |
|
•SEr1 and m or ft flash, and an index number, e.g. 1.0 is indicated.
Adjusting the dimensional units:
• m or ft is selected with the „+“ button | . |
Testing the display segments:
•Remove the adapter from the mecablitz
Press the button for the LC display light. All segments of the LC display must be indicated.
Return to the User Menu:
• Slide the main switch to OFF, and then to ON again.
52 | 53 |