14. Special functions Rapid - / Automatic cut-out

Fig. 30: Automatic cut-out

The Rapid function

Recycling times in the A and TTL modes depend on the amount of light required for the shot. Recycling takes 11 seconds max. when full-power flashes are fired. Should this be too long, the Rapid function comes to the rescue.

Use of the Rapid function is especially valuable when taking shots inside a room, where fast recycling is more important than a maximum light output. However, the guide number is reduced by 1 increment, e.g. from GN 40 (with ISO 100/21° film - 50 mm zoom) to GN 28 (with ISO 100/21° - 50 mm zoom).

Partial light output levels are not possible with the Rapid function.

Automatic cut-out

If you set the multi-function switch to the „clock symbol“, the flashgun is automatically switched off approximately 10 minutes after it was last used, thus protecting the batteries against inadvertent discharge.

The last used operating mode, or the last set user program is retained when the flashgun is switched off so that it becomes instantly available when the flash is

switched on. Press the „+“ or - button

to switch on again.

14. Special functions

m-ft display

Testing the LCD segments and m-ft changeover (Service Menu)

The Service Mode 1 has to be called in order to check the LCD segments and to change over the dimensional units (m = meter; ft = feet).

Only complete the settings described here! Do not press any other buttons than those described here, otherwise there is the danger that programmed data and user programs will be lost!

Calling the Service Mode 1:

Press the button

for the LC display light and simultaneously slide the main

switch

from OFF to ON. If a Pentax adapter is used, hold down button

for

at least 2 seconds after sliding the main switch .

 

SEr1 and m or ft flash, and an index number, e.g. 1.0 is indicated.

Adjusting the dimensional units:

m or ft is selected with the „+“ button

.

Testing the display segments:

Remove the adapter from the mecablitz

Press the button for the LC display light. All segments of the LC display must be indicated.

Return to the User Menu:

Slide the main switch to OFF, and then to ON again.

52

53

Image 29
Contents Mecablitz 40 MZ-3i Sensor Main switch LC display lighting / Modelling lightNomenclature Acoustic exposure verification on Film speed LC displayContents Please also open the back cover page with the illustrations ForewordBrief survey of the operating functions Stroboscopic mode, ch , pNever fire a flash in the immediate vicinity of the eyes Safety InstructionsPreparations Battery warning indicatorClose the battery compartment cover Mounting the flashgun on the camera Switching the flashgun on and offRemoving the Standard Foot or SCA adapter Mounting the Standard Foot or SCA adapterDirect way to good flash shots TTL flash modeSetting procedure for TTL mode Setting procedure for TTL Easy Mode Automatic flash modeEasy Mode To EMTo a Setting procedure for auto flash mode„ + or „ button See ch , p Also be set on the camera lensSetting procedure for manual flash mode Manual flash modeLock-in positions of reflector and head Bounce flashMounting the light reducing filter Bouncing the flash in the manual modeBouncing the flash in the auto and TTL modes With secondary reflectorMetz cordless TTL remote operation Setting procedure for Metz TTL remote operationTTL remote operation ControllerChecking the slave address Switching off the Metz TTL remote operationMetz cordless auto remote operation Setting procedure for Metz a remote operationRemote-Operation Distance values on the LC display disappearUsing the winder in auto and TTL modes Winder modeUsing the winder in the manual mode Setting procedure for manual mode with partial light output Partial light output levels in the auto modePartial light output levels in the manual mode Working with partial light output levels Stroboscopic modeFlash durations Macrophotography close-upsUse the „+ or „- button Setting procedure for stroboscopic modeFill-in flash in manual mode Fill-in flash in auto modeFill-in flash in daylight Complete illumination of shadow areasWorking with user programs Fill-in flash in TTL modeProg. flashes Procedure for storing a programCalling a stored program Zoom reflector Setting procedure for the Ex-Zoom modeZoom reflector main reflector Ex-Zoom-modePull-out/push-in wide-angle diffuser Or was, correctly exposed in the auto and TTL modeSpecial functions ML function Modelling Light AF measuring beamAF measuring beam ML-functionsSwitching on the „Beep function An intermittent beep signalling alarm soundsSwitching on with the controls locked Locking the controls key functionAdjusting the dimensional units Calling the Service ModeTesting the display segments Rapid functionExposure corrections in auto mode Technical DataExposure corrections in TTL mode Exposure correctionsFreq. fHz ModeRemarks 105Flashes per second = fHz ProcedureExample Partial light output PIncluded Optional extras No display in on switch position Troubleshooting hintsFlashing operating mode symbols Meaningless informationFill-in flash Alphabetical index