Pentax 40 MZ-3i operating instructions Mode, Freq. fHz, Remarks, 105, 100/21

Page 31

16. Technical Data

 

 

ISO

 

 

 

 

 

A P E R T U R E

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6-8

 

 

1

1,4

2

2,8

4

5,6

8

11

 

 

 

 

 

 

 

10-12-16

 

 

1

1,4

2

2,8

4

5,6

8

11

16

 

 

 

 

 

20-25-32

 

 

1

1,4

2

2,8

4

5,6

8

11

16

22

 

 

 

 

40-50-64

 

 

1

1,4

2

2,8

4

5,6

8

11

16

22

32

 

 

 

80-100-125

 

 

1

1,4

2

2,8

4

5,6

8

11

16

22

32

45

 

 

160-200-250

 

 

1,4

2

2,8

4

5,6

8

11

16

22

32

45

 

 

320-400-500

 

 

 

 

2

2,8

4

5,6

8

11

16

22

32

45

 

 

640-800-1000

 

 

 

 

2,8

4

5,6

8

11

16

22

32

45

 

 

1250-1600-2000

 

 

 

 

 

4

5,6

8

11

16

22

32

45

 

 

2500-3200-4000

 

 

 

 

 

 

5,6

8

11

16

22

32

45

 

 

5000-6400

 

 

 

 

 

 

 

 

 

8

11

16

22

32

45

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 2: Working aperture ranges

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prog.

Mode

Partial light

 

Number of

 

Freq. f(Hz)

 

ISO

Remarks

 

output

 

 

flashes N

 

 

1

 

TTL

 

P 1

 

 

 

-

 

 

-

 

 

100

 

 

 

2

 

TTL

 

P 1

 

 

 

-

 

 

-

 

 

100

 

 

 

3

 

TTL

 

P 16

 

 

 

-

 

 

-

 

 

100

 

 

 

4

 

A

 

P 1

 

 

 

-

 

 

-

 

 

100

 

 

 

5

 

A

 

P 16

 

 

 

-

 

 

-

 

 

100

 

 

 

6

 

M

 

P 32

 

 

 

-

 

 

-

 

 

100

5 frames/sec.

7

 

Strobo

 

P 16

 

 

 

5

 

 

1

 

 

100

 

 

 

8

 

Strobo

 

P 32

 

 

 

10

 

 

5

 

 

100

 

 

 

9

 

M

 

P 2

 

 

 

-

 

 

-

 

 

400

 

 

 

Table 3: Factory-assigned program places (zoom 50, f/5.6)

16. Technical Data

 

ISO

 

Zoom setting - Main reflector

 

 

 

20

24

28

35

50

70

85

105

 

6/9°

5,5

7

8

8,5

10

11

11,5

12,5

 

8/10°

6

8

9

10

11

12,5

13

14

 

10/11°

7

9

10

11

13

14

14,5

16

 

12/12°

8

10

11

12

14

15,5

16

18

 

16/13°

9

11

12,5

14

16

18

18,5

20

 

20/14°

10

12,5

14

15

18

20

20,5

22

 

25/15°

11

14

15,5

17

20

22

23

25

 

32/16°

12,5

16

17,5

19

23

25

26

28

 

40/17°

14

18

20

21,5

25

28

29

32

 

50/18°

15,5

20

22

24

28

31

32,5

35

 

64/19°

18

22,5

25

27

32

35

37

40

80/20°

20

25

28

30

36

39

41

45

 

100/21°

22

28

31

34

40

44

46

50

 

125/22°

24,5

31

35

38

45

49

51

56

 

160/23°

28

35,5

39

43

50,5

56

58

63

 

200/24°

31

39,5

44

48

56,5

62

65

71

 

250/25°

35

44

49

54

63

69,5

73

79

 

320/26°

39

50

55,5

61

71,5

79

82

89

 

400/27°

44

56

62

68

80

88

92

100

 

500/28°

49

62,5

69

76

89

98

103

112

 

650/29°

56

71

79

87

102

112

117

127

 

800/30°

62

79

87,5

96

113

124

130

141

 

1000/31°

69,5

88,5

98

108

126

139

145

158

 

1250/32°

78

99

110

120

141

156

163

177

 

1600/33°

88

112

124

136

160

176

184

200

 

2000/34°

98

125

139

152

179

197

206

224

 

2500/35°

110

140

155

170

200

220

230

250

 

3200/36°

124

158

175

192

226

249

260

283

 

4000/37°

139

177

196

215

253

278

291

316

 

5000/38°

156

198

219

240

283

311

325

354

6400/39°

176

224

248

272

320

352

368

400

 

 

 

 

 

 

 

 

 

 

Table 4: Guide numbers at maximum light output (P1)

56

57

Image 31
Contents Mecablitz 40 MZ-3i Nomenclature Main switch LC display lighting / Modelling lightSensor Acoustic exposure verification on Film speed LC displayContents Stroboscopic mode, ch , p ForewordPlease also open the back cover page with the illustrations Brief survey of the operating functionsNever fire a flash in the immediate vicinity of the eyes Safety InstructionsClose the battery compartment cover Battery warning indicatorPreparations Mounting the Standard Foot or SCA adapter Switching the flashgun on and offMounting the flashgun on the camera Removing the Standard Foot or SCA adapterSetting procedure for TTL mode TTL flash modeDirect way to good flash shots To EM Automatic flash modeSetting procedure for TTL Easy Mode Easy ModeAlso be set on the camera lens Setting procedure for auto flash modeTo a „ + or „ button See ch , pSetting procedure for manual flash mode Manual flash modeLock-in positions of reflector and head Bounce flashWith secondary reflector Bouncing the flash in the manual modeMounting the light reducing filter Bouncing the flash in the auto and TTL modesController Setting procedure for Metz TTL remote operationMetz cordless TTL remote operation TTL remote operationChecking the slave address Switching off the Metz TTL remote operationDistance values on the LC display disappear Setting procedure for Metz a remote operationMetz cordless auto remote operation Remote-OperationUsing the winder in the manual mode Winder modeUsing the winder in auto and TTL modes Partial light output levels in the manual mode Partial light output levels in the auto modeSetting procedure for manual mode with partial light output Macrophotography close-ups Stroboscopic modeWorking with partial light output levels Flash durationsUse the „+ or „- button Setting procedure for stroboscopic modeComplete illumination of shadow areas Fill-in flash in auto modeFill-in flash in manual mode Fill-in flash in daylightWorking with user programs Fill-in flash in TTL modeCalling a stored program Procedure for storing a programProg. flashes Ex-Zoom-mode Setting procedure for the Ex-Zoom modeZoom reflector Zoom reflector main reflectorSpecial functions Or was, correctly exposed in the auto and TTL modePull-out/push-in wide-angle diffuser ML-functions AF measuring beamML function Modelling Light AF measuring beam Locking the controls key function An intermittent beep signalling alarm sounds Switching on the „Beep function Switching on with the controls lockedRapid function Calling the Service ModeAdjusting the dimensional units Testing the display segmentsExposure corrections Technical DataExposure corrections in auto mode Exposure corrections in TTL mode105 ModeFreq. fHz RemarksPartial light output P ProcedureFlashes per second = fHz ExampleIncluded Optional extras Meaningless information Troubleshooting hintsNo display in on switch position Flashing operating mode symbolsFill-in flash Alphabetical index