Avaya LU250WAMP manual Speaker Connection, Output Wiring

Page 9

Output Wiring All output wiring connections are made to the terminal strip located under the right side access panel. Loosen the 2 Phillips-head screws on each side of the cover and remove the cover.

IMPORTANT: Before making any connections or wiring changes to the amplifier or any equipment connected to the amplifier, make sure that the amplifier is NOT plugged into an AC outlet.

NOTE: The amplifier does not have a power switch, so it must be unplugged in order to turn the power off.

Speaker Connection 70-volt speaker connections are made between the 70V and COM terminals on the output terminal strip (see Figure 7). Use a 22 AWG shielded, twisted pair cable (Com Code: 401882956, Pec Code: 2734-SPK). Connect the shield of the cable to the GND terminal of the output terminal strip. The COM and GND terminals of the output terminal strip are connected using a shorting clip. The shorting clip enables the amplifier output to act as an unbalanced output (one side of the output connected to ground). If desired, the output can be made to be a balanced output with no connection to ground. To balance the output, simply remove the shorting clip. All speaker connections remain the same as above including connecting the shield to the GND terminal.

NOTE: The amplifier output terminal strip also includes terminals for 25V and 70V speaker connections. These are provided for special applications and are generally not used.

70V 25V COM GND

Output Terminal Strip

RINGER VOLUME

MUSIC MUTE

MUSIC VOLUME

MIC VOLUME

TEL VOLUME

ALC

 

 

 

MUSIC IN

 

BRIDGING

 

 

CONTROLS

MIC

GND

TEL

CONTACT

TEL

TEL

MIC COM

BAL

BAL

RING

RING

+

 

T

R

 

_ +

_ +

Figure 7: Speaker Connection, Output Wiring

Page 9 of 12

Image 9
Contents Telephone Paging Amplifier 250-Watt Model Domestic and International Listings Contents Introduction Package ContentsMounting InstallationInput Wiring Wiring ConnectionsMicrophone Cable Bridging Inputs Speaker Connection, Output Wiring LUWMT1A Operation Indicators